Routing water pipes with pre-selecting
mixing tap(s)
Fig. B
Connect right-angled hot water connector (3) to equipment hot
water connector. Connect cold water connection fitting (4) to
cold water connector on equipment or submergible pump (16).

Control panel

When using control panels which are specific to the
vehicle or the manufacturer, the electrical connection
must be established in accordance with the Truma interface
descriptions. Any modification made to the Truma compo-
nents pertaining to this will lead to the invalidation of the guar-
antee, as well as to the exclusion of any claims for liability. The
installer (manufacturer) is responsible for providing instruc-
tions for use for the user as well as for identification printing
on the control panels.
Fig. D
When selecting the location, observe the fact that the control
panel (17) is not to be exposed to direct heat radiation. The
length of the connecting cable (18) is 2.5 m.
If it is not possible to instal the control panels flush with
the surface, Truma can provide a surface-mounting
frame (19) on request, as a accessory (part no. 40000-52600).
Drill a hole with 55 mm diameter. Feed the cable through to
the back and secure the control panel (17) with four screws
(20). Then fit the cover frame (21) on and lay the cable to the
Theme unit.
Truma offers side parts (22) in eight different colors for
finishing the cover frames (21) in a visually pleasing way.
Please ask your dealer.

Electrical connection 230 V

The 230 V electrical connection must always be made
by an expert (in accordance with VDE 0100, part 721 or
IEC 60364-7-721, for example, in Germany). The information
given here is not intended as instructions for you to carry out.
It is for assisting the expert assigned to carry out the job, act-
ing as auxiliary information when connecting the appliance!
Connection to the mains is effected by means of the cable,
3 x 1.5 mm
2
(e.g. hose line HO5VV-F) to a distribution socket
(not included in the scope of supply). A connection cable with
a mains plug os not permissible.
Always pay attention to use the correct colour code!
For maintenance or repair work there must be a disconnect-
ing device on the vehicle for all-pole disconnection from the
mains with a minimum contact gap of 3.5 mm.
Install splitting box (fig. A: 23) in the vicinity of the appliance,
on the vehicle floor or on the wall (length of cable 150 cm).