Troubleshooting
Fault
Your coolbox is not
working and the fan
wheel which can be
seen from the outside
is not turning.
The ignition is on and
the coolbox is not
working.
Pull the plug out of the
cocket and make the
following checks.
Your coolbox does not
cool satisfactorily and
the outer fan wheel is
not turning.
The coolbox does not
cool satisfactorily and
the outer fan wheel is
turning.
Possible cause
Suggested remedy
There is no voltage
The ignition must be switched on in
flowing from the
most vehicles for voltage to flow at
cigarette lighter in
the cigarette lighter.
your vehicle.
The cigarette lighter
Clean the socket of the cigarette lighter
socket is dirty.
with a non-metallic brush and a solvent,
This results in a poor
to ensure that the middle contact pin
electrical contact.
is clean. If the plug of your coolbox
becomes very warm in the cigarette
lighter socket, either the socket must
be cleaned or the plug has not been
assembled correctly.
The fuse of the
Replace the fuse (5 A) in the cigarette
cigarette lighter
lighter plug (3, Seite 3, A).
cable has blown.
The vehicle fuse has
Replace the vehicle cigarette lighter
blown.
fuse (usually 15 A). Please refer to the
operating manual of your vehicle.
The fan motor is
This can only be repaired by an
defective.
authorised customer services unit.
The ventilator motor
This can only be repaired by an
for the inner motor is
authorised customer services unit.
defective.
The Peltier element
is defective.
The integrated mains
This can only be repaired by an
adapter is defective.
authorised customer services unit.
Troubleshooting