IMPORTANT!!
Microbial contamination
A personal use of the nebulizer and of the accessories is recommended in order
to avoid any risks of infection.
Interactions
The materials used that come into contact with drugs have been tested with a
wide range of drugs. However, due to the variety and continuous evolution of
the drugs, the possibility of a chemical interaction cannot be excluded. Once
opened, the drug should be used as soon as possible, and prolonged contact
between drug and nebulizer should be avoided.
The use of ESSENTIAL OILS can cause damage to the nebulizer.
Disposal: to safeguard the environment, when the appliance has reached
the end of its life take it to an authorized electric appliance disposal center
where the raw materials can be recycled.
UNIT TECHNICAL FEATURES
Mod. MEDINEB F700
~
Voltage :
230V
50Hz 140VA 115V
Fuse :
T 2A - 250V
In compliance
Dir. 93/42/EEC
with:
(EN 60 601-1/A2)
Approvals:
Operating pressure (with nebulizer): 0.8 bar approx.
Max pressure:
Compressor air output:
Dimensions:
Weight:
Sound level (at 1 m):
Continuous use
SYMBOLS
Class II unit
Type B unit
Warning: follow the
"Instructions for use"
Alternating current
RAPIDFLAEM 2 NEBULIZER– TECHNICAL FEATURES
Capacity max:
*Aerosol output: with cap B
*Particle:
*Average values measured with 0.9% saline solution.
Certified with TSI Aerosizer 3220 computerized laser system in
compliance with Flaem internal procedure.
Operating requirements: temperature min. 10°C; max 40°C
Storage requirements:
Operating/storage
atmospheric pressure:
Electromagnetic compatibility
This aerosol therapy unit is designed to meet the current requirements for electromagnetic
compatibility. However if you suspect that the unit is interfering with the operation of your
TV, radio or other electrical appliance, try relocating the unit until the interference ceases.
Alternatively try plugging the unit into a different power socket.
Warranty: The unit is under warranty from the dealer that sold you the unit.
The Manufacturer, the Retailer and the Importer are responsible for safety, reliability and
performance of the unit only if: • the unit is used in accordance with the instructions for
use; • the electrical system of the facility where the unit is used adheres to IEC standards;
• assembly, additions, recalibrations, modifications or repairs are carried out by authorized
personnel.
The manufacturer reserves the right to introduce technical changes.
~
60Hz 180VA
T 3A - 250V
0051
LATEX
7 ml
0.25 ml/min approx.
without cap B
0.51 ml/min approx.
MMAD 2.8 µm
with cap B
MMAD 3.1 µm
without cap B
air humidity min. 10%; max 95% RH
temperature min. -25°C; max 70°C
air humidity min. 10%; max 95% RH
min. 690 hPa; max. 1060 hPa P
~
220V
60Hz 160VA 100V
T 2A - 250V
2.5 bar approx.
10 LPM approx.
20x27x10.5 cm
2.3 Kg
58 dB (A) approx.
Switch OFF
Switch ON
Never use the unit while
having a bath or shower
Latex Free
~
50/60Hz
T 5A - 250V