IMPORTANT NOTES
Always apply clamping tool
completely and at right angles.
The jointing technology must lie
in the clamping tools over its
entire surface.
Make sure fitting is correctly
seated in tool. Applying the tool
to the wrong fitting collar will
over-compress the joint!
Your tool is equipped with the
REHAU RO expander system. In
order to avoid damage to the
pipe, do not use REHAU RE
expander system parts (until
1996) with RO expander system
components.
Caution!
Do not touch moving parts (risk
of trapping fingers!)!
28
Always insert expanding tool into
pipe up to the stop. Do not tilt
the expanding tool.
Never use with damaged expan-
der head as this will damage the
pipe. Replacements are available
from your dealer or from the
REHAU sales office.
If using an expander bit, make
sure that the expander bit is in
the correct position (fully in the
jaws) before starting the tool.
Check for clamping of the bit in
the jaws (avoidance of falling
out).
Regularly grease the expander
cone (tube of lubricant is atta-
ched). Do not apply too much
grease on to avoid surplus grea-
se from entering the pipe.
Caution!
Do not apply grease on the sur-
face of the expanding segments
which get in contact with the
pipe.