Produktgruppe 512
4 von 24
en
Parts required
Quantity
Mat. no.
1
07496300
Note
Service and repair work should only be carried out by a suitably qualified technician (with specialist training,
knowledge and experience, and recent related work experience) in accordance with all appropriate local and
national safety regulations.
Servicing, modification, testing and maintenance of electrical appliances should only be carried out in
accordance with all appropriate legal requirements, accident prevention regulations and valid standards.
All regulations of the appropriate utility supply companies and standards relating to safety (not limited to
electrical safety) are to be complied with.
Danger!
Even with the machine switched off, mains voltage may be applied to some components.
Before any service work is commenced, the machine must be disconnected from the mains. Suitable
measurements must be made to ensure that this is the case.
A general visual check should always be carried out.
Incorrect conversion or service work could lead to a risk of fire or gas explosion.
Note
The fitting kit Mat. no. 07496300 for PW 6241 and PW 6321 contains the following:
1 flow meter
1 adapter for water intake
2 seals 3/4 16 x 23.8 x 1.5
1 white sticker 99 x 1 x 38.1
Various cable holders 98 x 2.5
1 cable through-feed M12 x 1.5
1 wiring diagram for multifunction module 07 MF07 PW flow meter
1 reducing bush 1 internal thread x 3/4 internal thread, brass
1 pipe nipple, 3/4 external thread
1 reducing piece 1 external thread x 3/4 internal thread, brass
Fitting instructions
List of illustrations:
Fig. 1, connection of flow meter to a 1 stopcock
Note
An initial requirement for fitting the flow meter is that a module 7 flow meter is already fitted in the machine.
29.04.2009
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
Designation
Flow meter fitting kit
M.-Nr. 07485100