Cabling
The ÉPIX™ Tile 2.0 receives both power and data from the ÉPIX™ Drive 642. Each
ÉPIX™ Drive 642 can power and control four ÉPIX™ Tile 2.0s.
The ÉPIX™ Tile 2.0 connects to the ÉPIX™ Drive 642 with shielded twisted pair
cables terminated with RJ45 connectors. The cables and connectors must have a
minimum specification of Cat5. These cables are not included, but are easily obtained
at any electronics or office supply store.
The ÉPIX™ Drive 642 has four RJ45 ports, one for each ÉPIX™ Tile 2.0.

Cabling Diagram

·
The cables between the ÉPIX™ Tile 2.0s and the ÉPIX™ Drive 642 must be
shorter than 10 m (32 ft).
·
Only a single ÉPIX™ Tile 2.0 can be attached to each RJ45 port on the ÉPIX™
Drive 642.

Configuration

ÉPIX™ Tile 2.0s are configured with the ÉPIX™ Drive 642, and the configuration
settings depend on the communication protocol being used (Art-Net™ or Kling-Net). In
either case, the Choice Pixel option on the ÉPIX™ Drive 642 must be set to 48x12.
For more information about configuring the ÉPIX™ Drive 642, see the product's User
Manual,
which
http://www.chauvetlighting.com/product-manuals-literature/. Art-Net™ is designed and
copyrighted by Artistic Licence Holdings Ltd.