Lista De Códigos De Reporte Contact Id - Paradox DIGIPLEX EVO48 V2.1 Guía De Programación

Publicidad

Evento en el Sistema
Late to Arm by User
Zone Excluded on Force Arming
Zone Went Back to Arm Status
Printer fault restore
Module AC restore
Module battery restore
Module Auxiliary supply restore
Fail to communicate with monitoring station
Module RF low battery
Module RF supervision trouble
Module RF battery restore
Module RF supervision restore
Cold Start
Warm Start
Test Report engaged
Listen-In request
WinLoad Login request
PC software communication finished
Installer on site
Installer programming finished
Module Fail to Communicate Restore
Missing PCS Module
GSM RF Jam
GSM No Service
GPRS FTC IPR512
Missing IP Module
IP No Service
IP100 FTC IPR512
Missing PCS Module Restore
GSM RF Jam Restore
GPRS FTC IPR512 Restore
Missing IP Module Restore
IP No Service Restore
IP100 FTC IPR512 Restore
Lista de Códigos de Reporte Contact ID
Si se usa el formato Ademco Contact ID, ingresar el valor hexadecimal de 2 dígitos (PROG. VALOR) para programar los códigos de reporte deseados en las
secciones [0201] a [0296], [0701] a [0832], [2001] a [2199], y [3900] a [3999].
CID#
Código de Reporte
ALARMAS MÉDICAS - 100
100 Alarma Médica
101 Emergencia Personal
102 Error al Reportar
ALARMAS DE FUEGO - 110
110 Alarma de Incendio
111
Humo
112 Combustión
113 Flujo de Agua
114 Calor
115 Estación de Sondeo
116 Conducto de Aire
117 Llama
118 Prealarma
ALARMAS DE PÁNICO - 120
120 Alarma de Pánico
121 Coacción
122 Silenciosa
123 Audible
124 Coacción - Acceso Autorizado
125 Coacción - Salida Autorizada
Código de Reporte Contact ID De Fábrica
al usar las secciones [4032] a [4037]
3 452 - Late to Close
1 57A - Zone Bypass
3 57A - Zone Bypass Restore
3 336 - Local printer failure restore
3 3A1 - AC loss restore
3 3A9 - Battery test failure restore
3 3AA - System trouble restore
1 354 - Fail to communicate
1 384 - RF transmitter low battery
1 381 - Loss of supervision - RF
3 384 - RF transmitter battery restore
3 381 - Supervision restore - RF
1 3A8 - System shutdown
1 3A5 - System reset
1 6A2 - Periodic test report
1 606 - Listen-In to follow
1 411 - Call Back Request
1 412 - Successful - download access
1 627 - Program mode Entry
1 628 - Program mode Exit
3 354 - Fail to Communicate Restore
1 552 - Radio Transmitter Disabled
1 552 - Radio Transmitter Disabled
1 552 - Radio Transmitter Disabled
1 354 - Fail to Communicate
1 552 - Radio Transmitter Disabled
1 552 - Radio Transmitter Disabled
1 354 - Fail to Communicate
3 552 - Radio Transmitter Restore
3 552 - Radio Transmitter Restore
3 354 - Fail to Communicate Restore
3 552 - Radio Transmitter Restore
3 552 - Radio Transmitter Restore
3 354 - Fail to Communicate Restore
Prog.
CID#
Código de Reporte
Valor
ALARMAS ANTIRROBOS -130
01
130 Robo
02
131 Perímetro
03
132 Interior
133 24 Horas
04
134 Entrada /Salida
05
135 Día /Noche
06
136 Exteriores
07
137 Antisabotaje
08
138 Prealarma
09
139 Verificador de Intrusión
0A
ALARMAS GENERALES - 140
0B
140 Alarma General
0C
141 Circuito Abierto
142 Cortocircuito
0D
143 Fallo de Módulo de Expansión
0E
144 Sabotaje de Sensor
0F
145 Sabotaje de Módulo de Expansión
10
146 Antirrobos Silencioso
11
147 Fallo de Supervisión de Sensor
12
Digiplex -EVO-
- 62 -
Código de Reporte SIA De Fábrica
al usar las secciones [4032] a [4037]
CJ - Late to Close
XW - Zone Forced
VV - Zone Included
VR - Printer Restore
AR - AC Restoral
YR - System Battery Restoral
YQ - Power Supply Restored
YC - Communication Fails
XT - Transmitter Battery Trouble
US - Untype Zone Supervision
XR - Transmitter Battery Restoral
UR - Untyped Zone Restoral
RR - Power Up
YW - Watchdog Reset
TX - Test Report
LF - Listen-In to follow
RB - Remote Program Begin
RS - Remote Program Success
LB - Local Program
LS - Local Program Success
YK - Communication Restore
YS - Communication Trouble
YS - Communication Trouble
YS - Communication Trouble
YA - Communication Fails
YS - Communication Trouble
YS - Communication Trouble
YA - Communication Fails
YK - Communication Restore
YK - Communication Restore
YK - Communication Restore
YK - Communication Restore
YK - Communication Restore
YK - Communication Restore
Prog.
CID#
Valor
150 24 Horas Sin Robo
13
151 Detección de Gas
14
152 Refrigeración
15
153 Pérdida de Calor
16
154 Filtración de Agua
17
155 Fisura Lámina Metálica
18
156 Fallo Diurno
19
157 Bajo Nivel de Gas
1A
158 Temperatura Alta
1B
159 Temperatura Baja
1C
161 Pérdida de Flujo de Aire
162 Detección Monóxido de Carbono
1D
163 Nivel del Tanque
1E
SUPERVISIÓN DE FUEGO - 200 Y 210
1F
200 Supervisión de Fuego
20
201 Presión Baja del Agua
21
202 CO2 Bajo
22
203 Sensor de Válvula
23
204 Nivel Bajo del Agua
24
205 Bomba Activada
206 Fallo de Bomba
Guía de Programación
Prog.
Código de Reporte
Valor
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38