1. INTRODUCTION
The installation can be completed with a power electricity meter installed in the consumer
unit of your home, which will be used both to know the current energy power and historical
energy consumption and to limit the consumed power managing the consumption of the
different thermal radiators connected not to exceed the maximum power established by the
user. (Energy manager).
2. CONTENTS
G Control PM
3. INSTALLATION
3.1. Device Installation
Disconnect the main switch of the consumer unit prior the device
installation.
Warning: The G Control PM is valid only for single-phase installations.
The G Control PM device is prepared to be installed in the consumer unit of your home.
a.
Install the device on the DIN rail in the consumer unit of your home.
b.
Connect the device using the appropriate wiring to a 230 V power supply.
c.
Connect the clamp energy meter to the G Control PM device and embrace the main
cable at the output of the main switch to record the total energy consumption.
CONSUMER
UNIT
Clamp Energy Meter
RF SIGNAL
EN
3.2. G Control Hub association
Warning: The association of G Control PM with a G Control Hub
connected to internet is required for the normal use of the device.
To link the G Control PM with the G Control Hub, once the discovery
mode in the hub is activated, press with the help of a paperclip or a
sharp object the interior button of the device. The LED light placed on
the power meter indicates the status of the linking.
LED Status
LED off
LED blinking every 2 seconds
LED blinking every half a second
4. ELNUR G CONTROL – ENERGY MANAGER
A maximum limit of total power installation can be set by the user using the web-app. The
system disconnects the thermal radiators following the priority order previously set when the
energy power is going to exceed the maximum power established by the user. If several
thermal radiators have the same priority, the system will first disconnect the one that is closer
to its set point temperature.
In addition, using the apps, real-time electricity consumption and historical consumption (daily,
monthly, annually) can be seen.