Gabarron TM-200T Manual De Instalación Y De Empleo página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
INSTALLATION AND OPERATING MANUAL
WALL-MOUNTED BATHROOM FAN HEATER
1. For your safety
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless thy have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety
Children must be under watch to avoid that they could play with the product
This fan heater is an extra-heating in the house. It must be used according to this concept.
Make sure that your supply rating corresponds to what specified on the rating plate i.e. 230 V AC,
50 Hz.
Don't leave your home while the appliance is in function: ensure in this case that the timer (if
present) is in OFF (0) position and the thermostat is in minimum position " ".
During function, place the heater in a safe position :
far (1 mt. ) from inflammable objects or furnitures;
-
leaving the air outlet space free : 1 mt. of free space in front of the heater;
-
not located immediately below a socket-outlet.
-
Do not leave animals or children touch or play with the appliance. Pay attention! The air outlet
grille gets hot during operation (more than 80° C i.e. 175° F)
WARNING: In order to avoid overheating, do not cover the heater. Do not hang anything on
the heater and do not cover it while it's working. This is clearly written on the cover of the product
or shown by the symbol
Do not use the heater in rooms with explosive gas or while using inflammable solvents or varnish
or glues.
If the cordset is damaged and you have to change it, do not do the job yourselves! Take the
product to an after sales authorised repair centre or to a person with similar skill and knowledge,
in order to avoid any risk of danger.
Do not use this heater close to showers, baths, swimming pools.
The appliance must be positioned so that the plug is always accessible.
The heater shall not be placed just under a wall socket
Do not mount the product on walls made from synthetic material.
2. Positioning
Only use the heater if it has been mounted on the wall in a vertical position;
This heater is fitted with a double electrical insulation circuit (class II) and therefore does not
require an earth connection.
This heater is water resistant to IPX4. It can therefore be used in bathrooms or other areas
subject to humidity AS LONG AS IT IS NOT INSTALLED WITHIN THE PERIMETER OF BATH
TUBS OR SHOWERS. This means that it cannot be installed in the areas marked as VOLUME 1
in figure 1.
It must never be possible for people in the bath tub or shower to reach the adjustment knob.
The disconnection devices of the supply rating must enalble the complete disconnection in case
of the category of overvoltage III
This heater must be correctly installed in compliance with the legislation in force in the country of
installation.
3. Installation
For the version fitted with a towel rail, BEFORE MOUNTING THE FAN HEATER ON THE WALL:
-
fit the towel rail into the holes underneath the product, figure 2
-
insert and tighten the 4 (short) screws contained in the bag, figure 3
-
The mimimum distance from the floor reported in figure 4 (30cm) changes because the
lowest towel rail must always be at least 60cm distant from the floor.
Mount the heater on the wall making sure to observe the minimum distances from the ceiling,
floor and other walls, as shown in figure 4
Drill three 6 mm diameter holes in the wall, as shown in figure 5
Insert the three wall plugs supplied with the product
Insert the 2 upper screws, contained in the same bag, taking care to leave a distance of 8 mm
between the head of the screws and the wall
Gripping the heater firmly, hook it onto the two screws; CAUTION! Before releasing the heater
make sure it is attached to the 2 screws.
Then secure the product with the lower screw, figure 6
4. Using the fan heater
The heater is fitted with the controls shown in figure 7
Model with thermostat
Starting from the anti-freeze position "8", turn the thermostat knob clockwise until you hear a
"click": the fan heater starts working at 2000W and the indicator LED lights up.
The thermostat maintains the required ambient temperature by automatically turning the heater
on and off. The more the knob is turned clockwise to a higher number, the higher the ambient
temperature will be. The highest position of the thermostat corresponds to approximately 35° C,
the bottom one (*) to about 5° C.
Using the thermostat
In a room with a temperature in excess of 35° C, the thermostat does not turn on the fan heater
even if it is at maximum.
Vice-versa, in a room with a very low temperature (below 5° C), the thermostat keeps the heater
constantly on, even if it is at minimum.
To optimise use of the thermostat, proceed as follows:
turn the thermostat knob to maximum and wait until a comfortable temperature is reached;
-
then turn the thermostat knob anti-clockwise until you hear a " click" and the heater turns off;
-
turn the thermostat knob clockwise just a little;
-
in this position, the thermostat will maintain the selected ambient temperature.
-
Model with thermostat and 60' timer
This model of fan heater is fitted with two knobs, one for the 60' timer and the other for the
thermostat.
2 different operating modes are available:
A
Maintenance of ambient temperature:
Starting from the anti-freeze position "8", turn the thermostat knob clockwise until you hear
a "click": the fan heater starts working at 1200W and the indicator LED lights up.
The thermostat maintains the required ambient temperature by automatically turning the
heater on and off. The more the knob is turned clockwise to a higher number, the higher the
ambient temperature will be. The highest position of the thermostat corresponds to
approximately 35° C, the bottom one (*) to about 5° C.
To adjust the thermostat, see the USING THE THERMOSTAT section above.
B
Rapid heating

Publicidad

Tabla de contenido
loading

Tabla de contenido