8
Settings & Adjustments
8.1 Detection beam direction
The LC-171 detection beam direction may vary between 0º and 180º.
In order to change the detection beam direction rotate the internal detection element
housing to the desired direction.
8.2 Detection range setting
The LC-171 detection range may vary between 3m (10 ft) and 12m (39 ft), while installed on
1.2m (4 ft.) height above the ground surface.
Changing the detection range is achieved by sliding the upper detection element up or
down.
10