16 • ENGLISH
b. Input voltage too high: The inverter will automatically
shut down when DC input voltage exceeds 15.5V ± 0.5V,
as this can harm the unit.
c. Thermal shutdown protection: The inverter will
automatically shut down when the unit becomes
overheated.
d. Overload/Short circuit protection: The inverter will
automatically shut down when a short circuit occurs.
OPERATING TIPS
The inverter should only be operated in locations that are:
a. Dry: Do not allow water or other liquids to come into
contact with the inverter.
b. Cool: Surrounding air temperature should ideally
be 10°C and 20°C (50°F and 68°F). Keep the inverter
away from direct sunlight, when possible.
c. Well-Ventilated: Keep the area surrounding the
inverter clear to ensure free air circulation around
the unit. Do not place items on or over the inverter
during operation. The unit will shut down if the internal
temperature gets too hot. The inverter will auto-reset
after it cools down.
d. Safe: Do not use the inverter near flammable
materials or in any locations that may accumulate
flammable fumes or gases. This is an electrical
appliance that can briefly spark when electrical
connections are made or broken.
CARE AND MAINTENANCE
Storage
1. Ideal storage temperature range is 0°C and 40°C
(32°F and 104°F).
2. Store and use in a cool, dry place with adequate
ventilation for all-around air circulation.
3. Avoid locations that are exposed to heating units,
radiators, direct sunlight, or excessive humidity or
dampness.
Fuse replacement
This inverter is equipped with multiple internal fuses.
Normally, these fuses will not "blow" unless there is a
serious problem inside the unit. Internal fuses are
replaceable; however, only trained personnel should
attempt fuse replacement. If the unit is damaged during
fuse replacement, the warranty may be voided.
The fuse in the DC accessory outlet plug is user-
replaceable. Make sure to first disconnect the outlet plug
from any 12V DC power source; then replace the fuse with
one of the same rating and type.
PROTECTING THE ENVIRONMENT
Separate collection. This product must not be
disposed of with normal household waste.
Should you find one day that your BLACK+DECKER
product needs replacement, or if it is of no further use to
you, do not dispose of it with household waste. Make this
product available for separate collection.
Separate collection of used products and packaging
allows materials to be recycled and used again.
Re-use of recycled materials helps prevent
environmental pollution and reduces the demand
for raw materials. Local regulations may provide for
separate collection of electrical products from the
household, at municipal waste sites or by the
retailer when you purchase a new product.
ACCESSORIES
The performance of your tool depends on the accessory
used. BLACK+DECKER and Piranha accessories are
engineered to high quality standards and designed to
enhance the performance of your tool. By using these
accessories you will get the very best from your tool.
SERVICE INFORMATION
BLACK+DECKER offers a full network of company-owned
and authorized service locations. All BLACK+DECKER
Service Centers are staffed with trained personnel to
provide customers with efficient and reliable power tool
service. For more information about our authorized
service centers and if you need technical advice, repair,
or genuine factory replacement parts, contact the
BLACK+DECKER location nearest you, or visit us at
www.BlackandDecker-la.com
SPECIFICATIONS
Maximum continuous power: 400 W
Surge capacity:
USB port:
B2C
B3
Input voltage:
Low voltage alarm:
Low voltage shutdown:
Thermal shutdown:
Wave form:
Fuses:
Input cables:
Operating temperature:
Storage temperature:
Operating/Relative humidity: 5% to 95% non-condensing
PI400LA
800 W
5V DC
500 mA
2100 mA
12.8 V
11.0 V ± 0.3 V DC
10.5 V ± 0.3 V DC
Automatic
Modified sine wave (MSW)
Internal / 12 V DC accessory
plug: 12 A
Battery clip cables / 12 V DC
accessory plug
10°C and 20°C
(50°F and 68°F)
0°C and 40°C