4) ATTACHING HOSE TO COMPRESSOR (See Fig. 7 - 9)
•
Make sure the air compressor is off and unplugged.
•
Apply seal thread tape to both ends of the coil hose.
•
Insert one threaded end of the hose into the open end
of female connector. Hold the end of the hose with a
9/16 in. wrench and use a 5/8 in. wrench on the female
connector to tighten securely.
•
Attach quick coupler to other end of the hose. Hold the
end of the hose with a 9/16 in. wrench and use a 11/16 in.
wrench on the quick coupler to tighten securely.
NOTE: Be careful not to allow threads to become
cross-threaded.
Do not attach air chuck or other tool to the
WARNING:
open end of the hose until start-up has been completed.
•
Firmly grasp the open end of the hose; hold facing
away from yourself and others.
•
Insert the female connector end of the coil hose into the
air outlet on the air compressor. Push the connector
firmly until you hear it click into place.
•
To disconnect the hose, push the external ring nut of
the quick coupler backward.
5) BREAKING IN THE PUMP (See Fig. 9 - 10)
•
Check and tighten all bolts, fittings, etc.
•
Place the switch in the OFF position and plug in the
power cord.
•
Open the drain valve completely.
•
Turn the air compressor ON ( l ) and run the air
compressor for 10 minutes to break in pump parts.
•
Place the switch in the OFF ( O ) position.
•
Close the drain valve.
8
ASSEMBLY
Pic. 4
Pic. 5
Pic. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
K13015FOM_Ver.0406