8
After each use, the pump must be cleaned to prevent corrosion and sprayer blocks caused by
pesticide liquids. Furthermore, regular cleaning of the product can prevent damage to crops in
the event that a product mixes with the previously used one.
Clean the surface of the pump with a damp cloth. Fill the tank with water and shake the pump,
then operate it in order to spray out the liquid or to evacuate it through the drain plug. The filters
of the tank can be removed for cleaning with water.
Drain plug
Unscrew the drain plug to drain all the water used to clean / rinse
the pump. Screw the cap back on after cleaning.
Filter cleaning
If there is liquid in the tank, close the valve (2) before opening the
filter (1) for cleaning. Once the valve is closed, the filter can be
removed and cleaned with water.
9
The pump should be kept in a dry place away from children. Do not keep it unused for too long
as it may cause damages to the battery. The pump should not be stored at temperatures below
15°C.
72
Art. 301 / Art. 302
Wheelbarrow battery pump 40 L and 60 L
Cleaning and maintenance
Storage
Art. 301 / Art. 302
Wheelbarrow battery pump 40 L and 60 L
Troubleshooting
Problem
Causes
1. A fuse has melted
2. Battery out of power
3. Power switch has been
The motor fails to run after
damaged
being powered on
4. Power wires
come off
5. Motor damaged
Abnormal sounds with the
1. The fastening screws of
motor in operation
pump are loosen
1. The inlet and outlet pipes of
Leakage occurs to the
the pump are loosen or broken
underside of the base
2. Caps or seals are damaged
1. Low pressure
2. The holes inside the
sprayer are clogged
Poor atomization results
3. The joints of the pipes lose
4. The battery is low
5. The tube is bent
For further information about the product, please contact info@stockergarden.com.
Sign up to our newsletter and keep up to date with our latest news info@stockergarden.com
10
Solutions
1. Replace it
2. Recharge
3. Replace the
switch
4. Disassemble the base to
reconnect the wires
5. Replace the motor
1. Tighten the screws
1. Disassemble the base to
tighten the pipe clam; repair it
2. If necessary, replace the
caps and gaskets
1. Increase the pressure
2. Remove
impurities
3. Tighten the joints
4. Recharge the battery
5. Check that the tube is
not bent
73