English
HOW TO HANDLE A CORE BIT
When a core bit is used, large diameter holes and blind
holes can be drilled. In this case, use optional accessories
for core bits (such as a center pin and core bit shank) for
more efficient operation.
1. Mounting
CAUTION
Prior to mounting a core bit, always disconnect the
plug from the receptacle.
(1) Mount the core bit on the core bit shank. (Fig. 15)
Before that, feed oil to the screw portion of core
bit shank for easy dismounting.
(2) Mount the core bit shank on the main body in the
same manner as in mounting the drill bit and the
bull point. (Fig. 16)
(3) Insert the center pin into the guide plate until it
reaches the extremity.
(4) Fit in the guide plate by aligning its concaved
portion with the core bit tip. When the position of
the concave is shifted by turning the guide plate
right or left, the guide plate never slips off even
when the drill is used in a downward direction.
(Fig. 17)
2. Drilling holes
(1) Insert the plug into a receptacle.
(2) A spring is built in the center pin. By straightly and
gently pressing it to the wall or floor surface, the
entire surface of the core bit tip attains contact to
start the hole drilling job. (Fig. 18)
(3) When the hole depth reaches approximately 5 mm,
the hole position can be determined. Then remove
the center pin and guide plate from the core bit
and continue the hole drilling job.
CAUTION
When removing the center pin and guide plate,
always disconnect the plug from the receptacle.
3. How to dismount the core bit
By holding the drill (with the core bit inserted) in
an upward position, drive the drill to repeat impact
operation two or three times, whereby the screw
is loosened and the drill becomes ready for
disassembly. (Fig. 19)
Remove the core bit shank from the drill, hold the
core bit with one hand, and strongly strike the head
of the SDS max shank portion of the core bit shank
with a manual hammer two or three times, whereby
the round head screw is loosened and the drill is
ready for disassembly. (Fig. 20)
HOW TO REPLACE GREASE
This machine is of full air-tight construction to protect
against dust and to prevent lubricant leakage. Therefore,
the machine can be used without lubrication for long
periods. Replace the grease as described below.
1. Grease replacement period
After purchase, replace grease after every 6 months
of usage. Ask for grease replacement at the nearest
Hitachi Authorized Service Center. Proceed for
replacement of grease.
2. Grease replenishment
CAUTION
Before replenishing the grease, turn the power off
and pull out the power plug.
9
All manuals and user guides at all-guides.com
(1) Remove the crank case cover and wipe off the
(2) Supply 20g of Hitachi Electric Hammer Grease A
(3) After replenishing the grease, install the crank case
MAINTENANCE AND INSPECTION
1. Inspecting the tool
2. Inspecting the mounting screws:
3. Maintenance of the motor
4. Inspecting the carbon brushes (Fig. 22)
5. Replacing carbon brushes
NOTE
Due HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT
Correct connection of the plug
The wires of the main lead are coloured in accordance
with the following code:
As the colours of the wires in the main lead of this tool
may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black. The wire
coloured brown must be connected to the terminal
grease inside. (Fig. 21)
(Standard accessory, contained in tube) to the crank
case.
As the tube contain 30g of grease, supply 2/3 of
the contained grease.
cover securely.
NOTE
The Hitachi Electric Hammer Grease A is of the low
viscosity type. If necessary purchase from an Hitachi
Authorized Service Center.
Since use of a dull tool will degrade efficiency and
cause possible motor malfunction, sharpen or
replace the tool as soon as abrasion is noted.
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Failure
to do so could result in serious hazard.
The motor unit winding is the very "heart" of the
power tool. Exercise due care to ensure the winding
does not become damaged and/or wet with oil or
water.
The Motor employs carbon brushes which are
consumable parts. When they become worn to or
near the "wear limit", it could result in motor trouble.
When an auto-stop carbon brush is equipped, the
motor will stop automatically. At that time, replace
both carbon brushes with new ones which have the
same carbon brush Numbers shown in the figure.
In addition, always keep carbon brushes clean and
ensure that they slide freely within the brush holders.
Loosen the two set screws and remove the tail
cover. Remove the brush caps and carbon brushes.
After replacing the carbon brushes, tighten the brush
caps securely and install the tail cover with securely
tightening two set screws.
Blue:
— Neutral
Brown:
— Live