1. Development and manufacture
asecos GmbH, D-63584 Gründau
Safety and Environmental Protection
2. Serial No.
The serial number can be found on the type plate at the upper right corner section inside the cabin.

3. Safety information

• Only use the cabins when they are in proper condition.
• Observe the maximum weight with which the cabin may be loaded.
• Keep the outlet opening in the ceiling clear at all times.
• Take note of all information in these operating instructions.
• Observe accident prevention regulations and workplace regulations.
4. Protected rights
A variety of commercially protected rights have been registered in order to protect the innovation, construction and design.
5. Preparing the smoke & talk for operation and use
Before setting up the smoke & talk smokers' lobby it is necessary to check that the ground can support it. The point lo-
2
ading (over approx. 20 cm
) of the types st.203, st.328 and the st.453 is about 100 kg at each of the cabin's supporting
feet.
The cabin may only be used in enclosed, dry areas. The room must be at least 2.4 m high. The volume of the room in
3
3
3
which the cabin is set up must be at least 17m
for type st.203, 27m
for type st.328 and 37m
for type st.453.
Before delivery, the necessary arrival checklist must be completed.
The conditions governing erection of the cabin are very flexible. The cabin can be located in an open space in the cen-
tre of the room, with one of its ends against the wall, with its back to the wall, in a corner of the room, or in a recess. It
must, however, be remembered that the cabin is not a piece of furniture, and cannot simply be moved from place A to
place B. If it has to be moved, the cabin must be dismantled and re-erected at its new site. This must be done by an au-
thorized asecos service technician.
The floor must be flat to within the specification of DIN 18202 . (Dimensional tolerances for building construction).
The cabin's supporting feet can compensate for differences in height of between plus/minus 10 mm.
The same applies to the alignment of the adjustable tables. No special demands are placed on the compression strength
of the floor covering. We only advise against the use of plastic flooring with foam backing, since pressure marks on the
floor can result.
The cabin is assembled by authorised mechanics. A connection for electrical power cables will be found on the cabin.
Please connect the electrical cable supplied to an existing, earthed socket supplying mains electricity at 230 V. The green
LED on the filter monitor should light up. At the same time the equipment will begin to run in standby mode. Standby
mode is interrupted by entirely disconnecting the power supply. When someone enters the cabin, the movement sen-
sor will switch the fan to full power. The lighting will also switch on.
A mains electrical connection (a socket, earthed according to regulations) meeting the following specifications must be
available in the room where the cabin is set up: Voltage 230 V, Frequency 50 Hz, Current rating at least 10 A
6. Functional checks, care and maintenance, fault finding
The smoke & talk is an item of personal safety equipment, which, in accordance with workplace regulations and with
VDI 6022, must be serviced and have its function tested by an appropriately trained person at least once a year. The bi-
annual service carried out by asecos will check the function, clean or exchange the filter, and will check the condition
and function of all the cabin's components, cleaning them or repairing them if necessary.