I. INTRODUCTION
This Uninterruptible Power Supply (UPS) is a high quality product designed
to protect your computer system against information loss and damages
to computer peripherals like monitors and modems in case of a blackout.
All Koblenz UPS models feature RJ11 / RJ45 telephone jacks to protect
your computer modem against voltage spikes and surges coming
through your telephone line (cable not included). Selected models have
coaxial cable protector (see table 1).
USB/R models (see table 1) also include an integrated USB port that with
the Koblenz Protek Software gives you on screen warnings in case of
power failure (cable not included). If the blackout continues and your
computer is unattended, the Koblenz Protek Software will save and
close your open files and safely shut down your computer.
You can download the Koblenz Protek Software free of charge at
www.koblenz-protek.com
II. INSTALLATION AND USE
1. Place the UPS to avoid:
a. Direct sunlight
b. Excessive heat
c. Excessive humidity or contact with liquids
2. Plug the UPS directly into a properly grounded 3-prong outlet. The UPS
begins charging when connected to utility power and turned on. Charge
the UPS 24 hours before using for the first time.
3. Turn off your UPS. Plug your equipment into the battery backup outlets.
Do not plug surge protectors or power strips into battery backup
outlets.
a. To make sure that your computer or video equipment is protected
against a power failure it is important to know its volt / ampere rating
and compare it with your UPS capacity (see table 3). You may plug
one or more pieces of equipment into the UPS making sure that the
total power requirement does not exceed the UPS capacity.
b. If the UPS is overloaded, a red light will flash and the UPS will beep,
this will turn off when the extra load is disconnected.
c. Battery backup plus surge protection outlets (silver).
These outlets should be used for sensitive equipment such as
computers, monitors and external drives. Battery power is automatically
provided in case of power outage. Power (utility or battery) is not
supplied to these outlets when the UPS is switched off.
Do not plug in laser printers to battery backup outlets, if so the UPS
warranty is voided.
d. Surge Protection Outlets.
These outlets should be used for all others peripherals such a printer,
scanner, fax machine, etc. These outlets do not provide power
during a power outage.
MODELS
ON
ON
BATTERY
OVERLOAD
REPLACE
REPLACE
LINE
BATTERY
LEVEL
SUPRESSOR
BATTERY
7507-USB/R
7507-IR
Use with:
CPU, monitor,
modem, fax,
telephone,
answer machine
inkjet printer or
scanner.
professional 500
VA
BACKSIDE OF UPS
in
out
USB PORT
TEL. LINE/MODEM
Use with:
LASER
in
out
PRINTER,
COAXIAL LINE
scanner, inkjet
printer, fax,
modem,
telephone or
answer machine.
Æ
INPUT
CIRCUIT BREAKER
120 V - 60 HZ
PUSH TO RESET
Operating Instruction Manual
UPS Battery Backup.
Models: 7507-USB/R, 7507-IR, 5007-USB/R,
4. Hook up your telephone line to the UPS jack marked "TEL LINE". Using a
regular telephone cable (not included) hook up the UPS "MODEM" jack to
your computer's LINE IN jack. Finally, connect your telephone or fax to the
computer's TELEPHONE / LINE OUT jack (figure A).
5. Turn on your UPS, when the ON LINE light is on the UPS is ready.
6. If you want to install the Koblenz Protek Software connect a USB cable (not
included) from the USB port in the UPS to the computer. Insert the CD in
your computer and follow the instructions. Only models USB/R.
* In case of a blackout:
All models will emit a beep and the "ON BATTERY" light will flash. As the battery
depletes the pace of the beep will become faster.
If you have installed the Koblenz Protek Software and the USB cable, you will
also receive a warning message on your computer screen and the software
will automatically save your files and shut down your system before the
battery runs out.
III. STATUS INDICATORS
Placed on the front panel to indicate UPS status.
1. On Line (green): This indicator is lit when there is utility power.
2. On Battery (red): This indicator is lit when the UPS battery is powering the
battery backup outlets.
3. Battery Level: If the light is green the battery is totally charged; if it is yellow,
the battery has less than the 50% of the charge and if it is red, the UPS is
almost run out of battery.
4. Overload (red): This indicator is lit when the equipment connected to battery
backup outlets (silver) consume more than the UPS capacity. Remove one
or more pieces of equipment to the surge protection outlets until the light
and the beep turn off.
5. Replace Suppressor (yellow): This indicator is lit when the surge suppressor
is burnt out. It is necessary to take the UPS to a service center or to connect
a surge suppressor to it. The UPS continues working normally but it does
not protect against spikes any more.
6. Replace Battery (red): This indicator is lit when the battery is near to the end
of its useful life. The battery should be replaced. Failure to replace the battery
may result in insufficient runtime during a power outage.
IV. BATTERY
1. The battery automatically recharges whenever the UPS is plugged into an
electrical outlet and turned it on.
2. Average battery life is 2 to 3 years.
3. To buy a new battery, call toll free: 1-800-548-5741.
4. Koblenz batteries are sealed and maintenance free.
V. SAFETY
1. Keep your Koblenz UPS away from moisture and liquids.
2. Do not expose the UPS to direct sunlight.
3. Do not use for medical or life support equipment.
4. Plugging any domestic appliance (i.e. blender, iron, refrigerator, etc.) into
the UPS will void the warranty.
5. Black outlets should not be used to plug in laser printers.
MODELS
TOTAL OUTPUT CURRENT 10A
5007-USB/R,
5007-IR, 5007-I
USB PORT
Use with:
CPU, monitor,
modem, fax,
telephone,
INPUT
120V - 60Hz - 10A
answer machine
inkjet printer or
scanner.
MODEL:
5007-USB-R
5007-IR, 5007-I, 3007-IR and 3007-I
MODELS
3007-IR,
3007-I
Use with:
CPU and
Monitor.
Use with:
LASER PRINTER, scanner, inkjet printer, fax, modem,
telephone or answer machine.
300VA Max.
200 WATTS Max.
INPUT
120V - 60Hz - 10A
MODEL:
3007-ICR

Publicidad

loading

Este manual también es adecuado para:

7507-ir5007-usb/r5007-ir5007-i3007-ir3007-i