Setting The Baud Rate - ratiotec RTP 300 Instruccion De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

[EN]
Printing a test receipt
Turn off the device. Hold down the FEED key for several seconds. Simultaneously press POWER shortly.
The red and green lamp light up. Press FEED again, the RTP 300 will then print a test receipt. The red
light will flash if the paper roll is empty, if it has been placed incorrectly or the top cover is not closed.
Operation
Switch ON/OFF: Connect the RTP 300 to your device by means of the supplied cables for data transfer.
Turn on the printer by quickly pressing POWER until the green energy light appears. The RTP 300 is ready
for data transfer and printing. To turn off, press POWER until the power light disappears.
Note: Please turn off printer before removing or connecting any cable to avoid any possible damage.
Avoid high humidity and direct sunlight. Keep away from magnetic objects. During operation,
do not leave the RTP 300 unattended. Turn off when device is not being used.

Setting the baud rate

Note: Most ratiotec devices work with a baud rate of 9600 bps. Change the baud rate only if you are
working with a product the baud rate of which differs from 9600 bps.
To change the baud rate, please proceed according to the following steps:
1. When off: Press POWER until all three indicating lights light up.
2. Press POWER again. The red error light blinks.
3. Press FEED to set baud rate (see chart below).
4. The power light blinks as many times as you have pressed the FEED key. E.g. If you have pressed
FEED once, baud rate is 1200 and the power light blinks once.
5. Press POWER to confirm and exit.
Times „Feed" pressed
1x
2x
3x
4x
5x
6x
7x
8x
4
Baud Rate
Blinking Times
1200
1x
2400
2x
4800
3x
9600
4x
19200
5x
38400
6x
57600
7x
115200
8x
ratiotec Devices
coinsorter CS 250
rapidcount Compact | rapidcount S |
rapidcount T | rapidcount ST 150 |
RS moneyscale

Publicidad

Tabla de contenido
loading

Tabla de contenido