Lutron HomeWorks HRP5-120 Instrucciones Para La Instalación Y Para El Uso página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

RF Coverage Diagrams - Continued
Home C: 10,000 ft
2
(928 m
Hybrid
Repeater
60 ft (18 m) maximum
between RF Processors
and Repeaters, or between
Repeaters
RF Processor
RF Communication Notes
• RF Dimmers and Keypads must be located within 30 ft (9 m) of an RF Signal Repeater or an RF Processor.
• RF Signal Repeater must be located within 60 ft (18 m) of an RF Processor or another RF Signal Repeater.
• Multiple processors or repeaters may be necessary to provide adequate coverage. Up to 16 processors (with up to
4 repeaters each) may be connected together in a system.
• RF Dimmers cannot be controlled by the system and RF Keypads do not function until they are addressed and
programmed. See the HomeWorks Illumination Software online help.
Hybrid Repeater Link
RF Processor
30 ft (9 m)
maximum
30 ft (9 m)
maximum
60 ft (18 m)
maximum
2
) or greater - or multiple structures/buildings
RF Processor 1: Main
House
* Start
*
#
OK
P/N 292-153
1 2 3 4
Inter-Processor Link
1000 ft (305 m) maximum wire run distance
30 ft (9 m)
maximum
60 ft (18 m)
maximum
RF Processor 2: Guest
Hybrid
Repeater
House
RF Processor
Hybrid Repeater
30 ft (9 m)
maximum
Hybrid Repeater Link
1000 ft (305 m) maximum wire run distance
30 ft (9 m)
maximum
* Start
*
#
OK
P/N 292-153
1 2 3 4
9