SAFETY WARNINGS
• This is a professional product exclusively intended for use by trained personnel.
• This equipment contains parts subject to hazardous voltages.
• Fire hazard, never leave the equipment on unattended.
• Only install the product on mains protected according to law by a magnetothermic breaker and differential
circuit breaker. Failure to observe these instructions may lead to serious health hazards. Hazard of death.
• Do not install the switchboard in potentially explosive environments such as the spraybooths.
The only admitted part is the original Walcom
• This equipment has surfaces which become hot in particular conditions. Burn hazard. Wear specific protective
gloves to handle heated metallic parts (120°C-248°F).
• Do not open the control panel for any reason. Any operation on it must be performed with the electricity mains
completely cut off.
• Do not attempt to dismantle any part except for filters.
• Before any maintenance operations make sure the electrical and air mains have been cut off.
• Do not damage the connection wires between the control panel, heater and solenoid valve in any way.
In the event of damaged electrical parts, immediately cut off the electrical mains and contact the manufacturer.
• Any unauthorised repairs may cause serious safety hazards.
• Instruct involved personnel and always keep a copy of this manual near the equipment.
• Check booth grounding system efficiency.
FAILURES AND REMOVAL OF THEIR CAUSES
FAULT
REDUCED AIR
OUTPUT
NO SIGNAL FROM THE
CONTROL PANEL
HEATING TUBE
DOES NOT HEAT
THE SYSTEM DOES
NOT HEAT AIR
CAUSE
- Filters clogged
- Pressure set too low
- Insufficient mains pressure
- Solenoid valve blocked
- Incorrect installation
- No power
- Main switch off
- Line fuse blown
- Line fuse blown
- Incorrect installation
- Main switch off
- Tube fuse blown
- The tube is damaged
- The set temperature is insufficient
- The system is still heating
- Incorrect installation
- No power
- Main switch off
- Line fuse blown
- Internal malfunctions
- Insufficient flow and pressure
tube. Install the TD
-TD
®
3
PRO
- Check clog indicators and replace clogged
filters
- Set at least 4 bar/58PSI working pressure
- Make sure mains pressure is at least 6
bar/87PSI and that flow is adequate
- Switch to "REGENERATION" mode for
several seconds, several times
- Check electrical connections
- Check electrical connections
- Check switches
- Check the fuse 16A (230 V only)
- Check the fuse 500 mA vers. 230 V,
1A vers.115 V
- Check electrical connections
- Check switches
- Check the fuse 6.3A vers. 230 V- 8A vers.115 V.
- Replace the tube
- Check set temperature
- Wait 5 minutes without supplying air
- Check electrical connections
- Check electrical connections
- Check switches
- Check the fuse
- Contact customer service
- Use a compressor with at least 600 lt/ min-
21,18 cfm 5 bar/73 PSI