2.6.1. POSSIBLE FAILURES AND THEIR ELIMINATION

Warning! :
Only technically qualified service centres can perform the operations described
below!
Warning! :
Before resetting the safety thermostat, it is always necessary to eliminate the
problem causing its activation (only for models with indirect heating)!
Problem and possible cause
The content of the vat does not heat up:
the safety thermostat has been
activated.
The pilot burner is on but the main
burners do not light up:
loss of pressure in gas supply;
clogged injectors on main burners.
The pilot burner does not light up:
clogged injectors on pilot burner;
faulty ignition plug;
check the cable of the ignition plug.
The pilot burner does not remain lighted:
faulty thermocouple;
partially clogged injector on pilot burner;
faulty cock magnet.
Instruction manual for installation, maintenance and use
Gas Kettles
Access to components and operation
Safety thermostat
The safety thermostat can be reached by removing the lower
front panel once the two side screws have been unloosed.
Main burners
Remove the lower front panel.
Pilot burner
Remove the lower front panel. The pilot burner is in the front of
the combustion chamber.
Ignition plug and thermocouple
Remove the lower front panel.