Output protected with a safety fuse. If the fuse blows, a red led will light up in the FILTER button on
the mimic panel front.
NOTE: For correct operation, if you wish to pilot the filtration pump using an external relay/remote
switch, eliminate condenser C4.
This operation must be carried out by qualified staff, at an assistance centre.
Massaging water jet pump connection
Connect the massaging water jet pump power supply cable to the OUT 2 clamp (N and F).
It is possible to connect a pump with an overall power of 2.0HP. Maximum admissible load of
230V 1.6 KW.
Output protected with a safety fuse. If the fuse blows, a red led will light up in the HYDRO button
on the mimic panel front.
CODE
F5
F6
F7
F9
CAUTION!! Wiring and connection operations must be carried out by qualified staff. Only use
pumps with internal over-heating protection systems.
[OPERATION AND
Description of protection fuses
FUNCTION
Lighting fuse
Filtration pump fuse
Massaging water jet pump fuse
Internal electronic fuse
Periodic Maintenance and Checks
MAINTENANCE]
[V-1.16]
FUSE VALUE
250 V - T 3.15 A
250 V - T 16 A
250 V - T 16 A
250 V - T 1 A
AQUA spa
13