1
UV lamp housing
2
Quartz tube
3
Gaskets
4
UV lamp
5
Gasket lock
6
End cable
7
Contact cap
8
Ballast
3.2 Osmotic membrane replacement
Run water from the tap over the sink to reduce circuit pressure.
Disconnect the connection pipe on the RO VESSEL top.
Unscrew the RO VESSEL top.
With a clamp, remove the membrane.
Insert a new membrane.
Screw in the RO VESSEL top.
Insert the connection pipes.
3.3 Filter cartridge replacement
Original cartridges are available in two practical and convenient KITS.
For OASIS DP models - OASIS DP cartridge KIT -
1. SEDIMENT - PP melt blown filter 5 micron
2. CTO Chlorine-Taste-Odor carbon G.A.C.
3. VOC Volatile-Organic-Compound carbon block filter 5 micron
For OASIS DP SANIC models - OASIS DP SANIC cartridge KIT -
1. SEDIMENT - String wound SANIC filter 5 micron
2. SEDIMENT - PP melt blown SANIC filter 5 micron.
3. VOC Volatile-Organic-Compound carbon block filter 5 micron
1
3
4
5
6
2
7
8
|
11