Minimum load permitted:
5% of the W.L.L. applying to plate surface hardness 279 HV10.
10% of the W.L.L. applying to plate surface hardness 363 HV10.
EN
For clamps IP..H and IPU...H
08
10% of the W.L.L. applying to plate surface hardness 472 HV10.
The pivot(s) and the camsegment are the most critical parts in the clamp and require extra
attention during inspection. Ensure in any event for good light during inspection.
the most common areas of damage:
Observe the following rules during every inspection:
Pivot(s):
Reject when the sharpness of one ring is damaged or worn for 50% or
more.
Camsegment: Reject when the sharpness of one tooth is damaged or worn for 50% or
more.
Some illustrations have been included on the inside of the front cover of damaged and
worn (rejected) pivots and camsegments with explanations. In most cases however the
areas of damage are much less extensive. In doubtful cases an authorised repairer
should assess the clamp.
1.3
how to operate the clamp
IP10 - IPU10 lifting clamps are suitable for the lifting, turning and vertical transport of
steel plates and structures.
See illustrations 4-8 for part reference.
1.
Open the clamp by pulling the latch lever (A) towards the jaw (4).
2.
Place the clamp securely on the plate so that the jaw of the clamp rests
on the plate (E) (5).
3.
Pull the latch lever (A) towards the lifting eye (D). The clamp will now close and will
remain on the plate in pretensioned position, allowing lifting to commence (6).
4.
As soon as the load is at its destination let the crane hook descend until the clamp
is fully free of load, meaning that the lifting chain is no longer taut and the lifting
eye (D) of the clamp can move freely. To release the load pull the latch lever (A)
towards the jaw, allowing the clamp to be and remain opened (7).
5.
The clamp may now be used again immediately or put away in opened position.
This position will protect the teeth from damage (8).
Copyright © 2013 The Crosby Group LLC. All Rights Reserved.
1.4
A reliable clamp, a secure basis for lifting
10 year warranty preventive maintenance procedure:
During every maintenance service the most critical parts, being pivot(s), camsegment
and spring are replaced and, when necessary, any rejected parts will be replaced.
For clamps with a Working Load Limit (W.L.L.) of 9 ton or more, parts will be replaced
only when they no longer meet our standards.
10 year warranty repair procedure:
During every repair service the most critical parts, being pivot(s), camsegment, spring,
shafts and latch lever will be replaced and, when necessary, any rejected parts will be
replaced.
For clamps with a Working Load Limit (W.L.L.) of 9 ton or more, parts will be replaced
only when they no longer meet our standards.
Please consult www.crosbyip.com/warranty for more information on maintenance
procedures.
Maintenance without 10 year warranty: Annually clamps are subjected to inspection*
and parts will be replaced only when they no longer meet our standards.
*CrosbyIP authorised repairer