8. The following screen will appear. This means the gateway is entering binding mode.
9. Make sure the LED on the unit is turned off. If it is on, press the Link Key once to turn it
off.
10. Press and hold the Link button on the in-wall module for 3 seconds until its LED turn on
then release. The LED will start to flash.
11. The screen below will appear in 10 seconds if the process is successful and the LED
indicator will stop flashing.
Note: If the LED flashes rapidly 3 times after 30 seconds, this indicates the binding was
unsuccessful. Please refer to the Troubleshooting section.
Operation
The In-Wall module can be operated either remotely through the gateway, manually using a
connected wall switch, or manually through its own Control Button.
Using the gateway:
User can turn on/off and dim* the light bulb. The LED indicator on the module will also turn on
or off accordingly.
Using the external wall switch
For Binary switch :
- User can only turn on/off the light bulb. Diming function is not supported. A message will be
sent to the Gateway each time when the module is manually turned on or off.
For Tact/Push button switch :
- User can turn on/off and dim* the light bulb. A message will be sent to the Gateway each
time the button is pressed. Refer to the Control Button table below to configure the In-Wall
module for this type of switch.
Note: External dimmer type switch is not supported.
Using the Control Button
Refer to the table below:
Action/Status
Description
Quick press on the Control
On/off
button to turn on and turn off
the light bulb
When the light is ON, press
and hold the Control button.
Dimming*
The light bulb will dim up and
dim down repeatedly until the
button is released.
Change switch input
When device is OFF, press
from "binary switch
"link key" for over 5 seconds
mode" to "tact switch
but no more than 8 seconds.
mode" or vice versa.
*Note:
- This applies to dimmable type LED bulb only. Attempt to dim a non-dimmable LED bulb will
have unpredictable results and may cause damage to the LED bulb.
-The maximum brightness in 2-wire configuration shall be about 80% of the bulb's rated
power.
Whenever the module is powered up again, usually after a power-cut, it will send a message
to gateway to report its status.
2
LED indicator
LED on = Light is on
LED off =Light is off
LED remains on.
LED will flash the first time after
3 seconds and flash again after
5 seconds.
If pressed longer than 8
seconds the LED will flash 3
times indicating the change did
not take effect.