USING THE ELEMENT
1) Storing the master code or programming code
- This code allows you to modify the parameters of the coded keyboard from the front panel.
- Set the jumper in the centre of the circuit to the Prog position. The green LED illuminates.
=> Example of master code 485156
- Enter the following sequence 00 0 6 485156 #. The green LED blinks twice which indicates correct
programming.
- Please note, number 6 preceding the master code indicates the number of terms. This numeral must be
between 3 and 8 and correspond to the number of figures you want to program.
- Reset the jumper to the operating mode.
2 – Storing the access codes
- Enter the master code, the green LED illuminates.
Programming example for the first access code 1234
01 0 4 1234 #
Number of memory boxes
Example for programming the second five-number access code 45678.
02 05 45678 #
Note: In these cases, the relay actuated by a valid control is number 1.
3 – Programming the striker timeout
To set the timeout for relay no. 1 to 3 seconds, enter
31 03 #
The green LED blinks twice.
4 – Erasing a code
** 01 #
01 designates the memory box to be erased.
5 – Erasing all the codes
35 00 #. This sequence is used for resetting the coded keypad.
Note: The green LED remains illuminated for 30 seconds after a key is depressed for the last time. This
time corresponds to leaving the programming mode.
Under no circumstances can the master code be used as the door opening code.
WARNINGS TO BE RESPECTED
SAFETY INSTRUCTIONS
It is imperative that the transformer is installed on the DIN rail of a modular table or surface mounted on a non-
metallic support by using both clamp bolt holes. Of course, the terminal covers must be reinstalled; in addition, the
connection must be on an electrical installation complying with the NFC 15-100 standard for France and ONCE THE
WIRING IS COMPLETELY COMPLETED. Protection: the transformer is fitted with a thermal protection
'PTC'. In the event of damage or short-circuit, this must be done to recover the transformer protection
1. Disconnect the 230 V~ power supply (for at least 2 min.)
2. Repair if this is necessary
3. Reconnect the 230 V~ power supply
XO 502.indd 13
01
0
4
1234
Number of numerals Access code
ENGlISh
#
validation
4
5
21/10/2009 10:39:16