Timing advance processor setup
The timing advance processor's setup is made using a push-button and 2 LEDs mounted
as shown on the picture
The red LED
has a double function, while running normally it indicates when
l
advance is activated, during the programming stage it shows the option we
are altering, which is done by means of the flashes.
The green LED
shows the value of the selected option, also by means of
l
flashes.
The push-button
allows to select the different options of programming and
l
the different values within each option.
Programming mode
Connect the vehicle or turn it on, press the push-button and release it, you will seen that the
LEDs start flashing, in this case the red LED will flash, indicating that it is in option 1 (advance
curve), the green LED will flash once or several times indicating that the advance curve's
value is selected (1-6º , 2-9º, 3-12º or 4-15º ), if no change is made the LEDs will repeat the
previous sequence 5 times and return to the current mode (the red LED indicates activated
advance).
Options Selection
To pass from one option to the other, the push-button must be kept pressed until the red LED
remains on and then be released, for instance if it is in the option 1 (red LED 1 flash), keep
the push-button pressed until the red LED lights up, release the push-button, now the red
LED will flash twice (idling advance option). If the procedure is repeated, you will pass on to
the option 3 and so on until getting to the last option, if the procedure is repeated, you will
pass to the option 1.
Change of values
To alter the value of an option, enter in programming mode, select the option with the previous
procedure, once you are in the wanted option, each time it is shortly pressed, the value is
altered passing to the following one until getting to the last one, if you push once more shortly,
you pass to the first one.
5. Instructions Manual
Green LED (Value)
Red LED (Advance/Option)
Timing Advance processor connector
6°
9°
Advance curve
12°
15°
No
Idling Advance
Yes
No
Decelerating Advance
Yes
4
5
Number of cylinders
6
8
3
Technical features
Supply voltage:
10 ÷ 14,5 VDC
l
Timing advance processor's sizes:
l
Hight
Depth
Width
Kit's contents
ADP advance timing advance processor.
l
Cabling for ADP timing advance processor.
l
Fittings for electric installation .
l
Mounting Instructions.
l
6. Instructions Manual
1
PB
Red LED
Green LED
Flashes
Flashes
105 mm
35 mm
65 mm