JOLLY
unit to sit for extended periods of time after
sanitization.
1
Wash hands with a suitable antibacterial
soap.
2
Prepare at least two gallons of a warm (45-
60 °C 120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with two litres of
water) according to your local Health Codes and
manufacturer's specifications.
3
Place the parts in the sanitizing solution
following manifacture 's specifications (about five
minutes).
4
Place the sanitized parts on a clean dry
surface to air dry.
5
Wipe clean all exterior surfaces of the unit.
Do not use abrasive cleaner.
5. 3. 4 ASSEMBLY
1
Slide the drip tray into place.
2
Pinch tube faucet: push the dispensing
handle (1) and insert the pinch tube into its
vertical seat in the bowl bottom(2). Lightly pull
the pinch tube end downwards til itl is well
arranged (3) (see figure 5).
figure 5
3
Gravity faucet: install the faucet handle (1-
2) and the piston with its gasket (3) (see figure
6).
4
Fit the bowl gasket to the evaporator. Note:
the largest brim of the gasket must face against
the drip plate (see figure 8).
5
Place bowl on the unit. Wet the gasket for
ease of insertion.
JOLLY 5/2 - 5/3 - 5/4: be sure first that the faucet
top (1) is under the tooth jutting (2) out of the drip
plate (see figure 8).
14
figure 6
figure 7