Installation Guide /
Guía de instalación
for Oberon Model 1011-00-XX
para Modelo Oberon 1011-00-XX
1
Mark the screw locations on the wall using the included template or the
Model 1011-00 itself. Use a 3/8 inch drill on the marked hole locations.
Included wall anchors will work with 3/8-5/8 inch drywall. Insert the included
hollow tip wall anchors (molly bolts) in each of the holes. For each molly
bolt, press the hooks into the wall, this should prevent the bolt from rotating.
Tighten each of the screws sufficiently to expand the back of the bolt. Back
each of the screws out several turns. There should be enough clearance
between the bottom of the screw head and the rest of the molly bolt and wall
for the enclosure's keyhole slots to engage the screws.
Marque las ubicaciones de los tornillos en la pared usando la plantilla in-
cluida o el Modelo 1011-00 mismo. Use un taladro de 3/8 de pulgada en las
ubicaciones marcadas de los agujeros. Los anclajes de pared incluidos
funcionarán con paneles de yeso de 3/8-5/8 pulgadas. Inserte los anclajes
de pared de punta hueca incluidos (pernos de molly) en cada uno de los
agujeros. Para cada tornillo Molly, presione los ganchos contra la pared,
esto debería evitar que el tornillo gire. Apriete cada uno de los tornillos lo
suficiente como para expandir la parte posterior del perno. Retire cada uno
de los tornillos varias vueltas. Debe haber suficiente espacio entre la parte
inferior de la cabeza del tornillo y el resto del perno de molly y la pared para
que las ranuras del ojo de la cerradura del alojamiento encajen en los tornil-
los.
To attach other vendor's APs or a Cisco AIR-BRACKET-II, reference the AP
mounting legend. If there is not a hole pattern for your AP you can attach it
with the provided T-Bar mount shown in step 3d.
Para adjuntar AP de otros proveedores o un Cisco AIR-BRACKET-II, con-
sulte la leyenda de montaje de AP. Si no hay un patrón de agujeros para su
AP, puede adjuntarlo con el soporte de barra en T provisto que se muestra
en el paso 3d.
"Oberon" and all other marks where denoted are trademarks of Oberon Inc.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.
2
To attach the assembled mount on the wall, align the keyhole slots on the
back of the Model 1011-00 with the screws in the wall and slide the
mount down so that the screws are at the top of the slot. Tighten the
screws to secure the mount to the wall, and attach any necessary cables.
Para colocar el montaje ensamblado en la pared, alinee las ranuras con
forma de bocallave en la parte posterior del modelo 1011-00 con los
tornillos en la pared y deslice el montaje hacia abajo para que los tornil-
los queden en la parte superior de la ranura. Apriete los tornillos para
fijar el soporte a la pared y coloque los cables necesarios.
***It is important that the mount is securely fastened to prevent hu-
man injury or damage to the access point.
***Es importante que el montaje esté fijado de manera segura para
evitar lesiones en personas o dañar el punto de acceso.
3a
(Cisco APs Only) Cisco APs can be directly attached to the Model 1011-
00. Attach the data cable to the Cisco AP. Align the feet of the Cisco AP
with the Cisco AP slots on the bottom of the Model 1011-00 and slide
them into position as shown above. Insert the set screw shown above to
secure the AP.
(Solo los AP de Cisco) Los AP de Cisco se pueden conectar direc-
tamente al modelo 1011-00. Conecte el cable de datos al Cisco AP.
Alinee las patas del AP de Cisco con las ranuras de bocallave en la parte
inferior del modelo 1011-00 y deslícelos en su posición, como se mues-
tra arriba. Inserte el tornillo de bloqueo que se muestra arriba para
asegurar el AP.
©1999-2020 Oberon Incorporated. All rights reserved.
EPN 2043, 3324, 3336, 3338, 3339, 3611, & 3612 - Rev. 3/18/2020
3b
Aruba APs can also be directly attached to the Model 1011-00. Depend-
ing on the exact model of the Aruba AP being installed, it might be easier
to plug the data cable into the AP before mounting it onto the 1011-00.
(For Aruba 3XX Series APs Only) Align the mounting feet of the Aruba
AP with the stepped openings in the middle of the Model 1011-00 and
slide the AP into position. Insert the provided set screw as shown above
to secure the AP.
(For Aruba 5XX Series APs Only) Align the two (2) threaded holes and
(2) "D" shaped bosses of the Aruba AP with the four (4) corresponding
holes on the Model 1011-00 (See AP mounting legend on Page 1). The
AP should be aligned so that its data port is facing towards the wall. Use
two (2) screws to secure the AP to the 1011-00.
If it has not been done already, plug the data cable into the AP.
Los AP de Aruba también se pueden conectar directamente al modelo
1011-00. Dependiendo del modelo exacto del AP de Aruba que se esté
instalando, puede ser más fácil conectar el cable de datos al AP antes
de montarlo en el 1011-00.
(Solo para AP Aruba serie 3XX) Alinee los pies de montaje del AP
Aruba con las aberturas escalonadas en el medio del Modelo 1011-00 y
deslice el AP a su posición. Inserte el tornillo de fijación provisto como se
muestra arriba para asegurar el AP.
(Solo para AP Aruba serie 5XX) Alinee los dos (2) agujeros roscados y
(2) protuberancias en forma de "D" del AP Aruba con los cuatro (4) agu-
jeros correspondientes en el modelo 1011-00 (consulte la leyenda de
montaje del AP en la página 1) El AP debe estar alineado de modo que
su puerto de datos esté orientado hacia la pared. Use dos (2) tornillos
para asegurar el AP al 1011-00.
Si aún no se ha hecho, conecte el cable de datos al AP.
Mounting Solutions for WiFi Access Points
3c
(Meraki APs Only) Meraki APs can be attached to the Model 1011-00
through the use of the Meraki mounting bracket.
(MR45 APs Only) Align the "B" marked hole and slot of the Meraki mount-
ing bracket with two (2) of the 1011-00's "K" holes (See AP mounting legend
on Page 1).
(For Other Meraki APs) Align the Meraki bracket's "E" marked holes with
two (2) of the 1011-00 "K" holes (See AP mounting legend on Page 1).
The mounting bracket should be aligned so that the release tab is facing
away from the wall. Fasten the Meraki mounting bracket to the 1011-00
using two (2) of the included #6-32 screws.
Plug the data cable into the Meraki AP. Attach the Meraki AP to the Meraki
mounting bracket. Use one (1) of the screws included with the Meraki AP to
retain the release tab. For added security, use the Torx screw included with
the Meraki AP.
(Solo AP Meraki) Los AP Meraki se pueden conectar al Modelo 1011-00
mediante el uso del soporte de montaje Meraki.
(Solo MR45 AP) Alinee el orificio marcado con la "B" y la ranura del soporte
de montaje Meraki con dos (2) de los orificios "K" del 1011-00 (consulte la
leyenda de montaje del AP en la página 1).
(Para otros AP Meraki) Alinee los agujeros marcados con la "E" del
soporte Meraki con dos (2) de los agujeros 1011-00 "K" (consulte la leyenda
de montaje AP en la página 1).
El soporte de montaje debe estar alineado de modo que la lengüeta de
liberación quede hacia afuera de la pared. Sujete el soporte de montaje
Meraki al 1011-00 con dos (2) de los tornillos # 6-32 incluidos.
Conecte el cable de datos al Meraki AP. Fije el AP Meraki al soporte de
montaje Meraki. Use uno (1) de los tornillos incluidos con el Meraki AP para
retener la pestaña de liberación. Para mayor seguridad, use el tornillo Torx
incluido con el Meraki AP.