F2: Malfunction of evaporator
temperature sensor.
There is harsh sound during
operation.
Strong odours are emitted during
operation.
Water is leaking from the indoor
unit.
The air switch or protection
switch often interrupts power
supply.
Water or other liquid is splashed
into the unit.
Mains cord and mains plug are
overheated.

OPERATION TIPS

Cooling operation
Air conditioners absorb heat from indoor
and transmit the heat to the outdoor
unit in order to decrease the room
temperature. The cooling capacity will
increase or decrease according to the
outdoor temperature.
Anti-freezing function
If the unit is in COOL mode and in a
low ambient temperature, frost will be
formed on the heat exchanger of the
indoor unit. If the temperature of the
heat exchanger decreases below zero,
the compressor will stop operation to
protect the unit.

Heating operation

Air conditioners absorb heat from
outdoor and transmit the heat to the
indoor unit in order to increase the room
Check if the evaporator temperature sensor is
connected properly.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
Immediately stop operation, disconnect the
unit from the power supply and contact an
authorised service centre.
temperature. The heating capacity will
increase or decrease according to the
outdoor temperature.
Defrosting
the outdoor humidity is high, frost
will form on the outdoor unit during
extended operation. The heating
capacity will decrease. The unit may
stop operation during defrosting.
the indoor unit and outdoor unit will
stop operation.
flashes and the outdoor unit may emit
vapour. This is normal operation to
remove frost from the heat exchanger
of the outdoor unit.
will resume automatically.
ENGLISH
13