Fig. I
23
22
5. Fit bag inside the tank ensuring it is not folded
or pinched.
6. Replace dust extractor head onto the tank and
latch securely.
Removing and Disposing the Bag
(Fig. A, G, J)
1. Press the three position switch
and remove the battery.
2. Unlatch the tank latches
extractor head
6
from the tank
nOTE: It is normal for there to be a small amount of
dust in the tank even with the the bag properly installed.
3. Rotate the bag until the two tabs align with the two
notches on the dust extractor and remove the bag.
4. Once the bag is removed it can be sealed for disposal.
a. Peel the backing from the adhesive seal
b. Press the adhesive seal over the opening and
properly dispose of the bag. DO NOT reuse the bag.
Fig. J
24
Installing the Plastic Liner (Fig. A, I, K)
1. Press the three position switch
and remove the battery.
2. Unlatch the tank latches
extractor head
6
from the tank
3. Attach the plastic liner
28
on the bag opening past the two notches
the dust extractor as shown in Fig. I.
21
to the Off (O) position
3
4
and remove the dust
16
.
24
.
3
to the Off (O) position
4
and remove the dust
16
.
by passing the two tabs
21
on
22
4. Rotate the bag a quarter turn until the square edge
is facing upward.
5. Fold the plastic liner over the top edge of the tank.
Fig. K
28
16
6. Replace dust extractor head onto the tank and
latch securely.
Removing and Disposing the Plastic
Liner (Fig. A, I, K)
1. Press the three position switch
and remove the battery.
2. Unlatch the tank latches
extractor head
6
from the tank
nOTE: It is normal for there to be a small amount
of dust in the tank even with the the plastic liner
properly installed.
3. Peel the backing from the adhesive tape
top edge the plastic liner and seal the liner.
4. Rotate the plastic liner until the two tabs align with the
two notches on the dust extractor and remove the liner.
5. Peel the backing from the adhesive seal
in Fig. J.
6. Press the adhesive seal over the opening and properly
dispose of the bag. DO NOT reuse the bag.
MAINTENANCE
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories. An
accidental start-up can cause injury.
Cleaning
WARNING: Using a damp cloth, clean dust
from air vents at least once a week. Wear proper
ANSI Z87.1 (CAN/CSA Z94.3) eye protection and
proper respiratory protection as required by OSHA or
other governmental/provincial institutions for the
application being performed.
WARNING: Never use solvents or other harsh
chemicals for cleaning the non-metallic parts of
the tool. These chemicals may weaken the plastic
materials used in these parts. Use a cloth dampened
only with water and mild soap.
English
23
29
3
to the Off (O) position
4
and remove the dust
16
.
29
along the
. as shown
24
11