Required AC Mains
Cable
Model
IEC Protection Class
Socket Outlet (Vehicle
Interface)
Voltage & Current Rating 230VAC 50/60 Hz - 1-phase 32A
AC Maximum Charging
Output
Idle Mode Power
Consumption
Required Circuit Breaker
on AC Mains
Required Ground Fault
Protector on AC Mains
Required AC Mains
Cable
WLAN Connectivity
RFID / NFC Module (Supported
models only)
Material
Dimension
Dimension (-T2S models)
Dimension (Packing)
Weight
AC Mains Cable Dimension
Protection Degree
Operating Condition
Storage Condition
5x 6mm² (< 50m)
Outer Dimension: Ø 15-21 mm
ELECTRICAL SPECIFICATION
Charging station02-AC7 Series
Class I
Socket Outlet TYPE 2 (IEC 62196)
7.4 kW
3.5W
2P-40A MCB Type-C
40A - 30mA RCCB Type-A/Type-B
3x 6 mm² (< 50m)
Outer Dimension: Ø 12-18 mm
CONNECTIVITY
2.4 GHz Wi-Fi (IEEE 802.11n)
AUTHORIZATION
ISO-14443A/B and ISO-15693
MECHANICAL SPECIFICATION
Aluminum
180.0 mm (Width) x 646.7 mm (Height) x 183.5 mm (Depth)
180.0 mm (Width) x 646.7 mm (Height) x 197.3 mm (Depth)
245.0 mm (Width) x 710.0 mm (Height) x 270.0 mm (Depth)
10.7 kg , 12 kg with packing
Ø 15-21 mm for 22kW and 11kW versions
Ø 12-18 mm for 7.4kW and 3.7 kW versions
ENVIRONMENTAL SPECIFICATION
Ingress Protection
Impact Protectıon
Temperature
Humidity
Altitude
Temperature
Humidity
Altitude
English - 10 -
5x 4 mm² (< 50m)
Outer Dimension: Ø 15-21 mm
Charging station02-AC3 Series
Class I
Socket Outlet TYPE 2 (IEC 62196)
230VAC 50/60 Hz - 1-phase 16A
3.7 kW
3.5W
2P-20A MCB Type-C
20A - 30mA RCCB Type-A/Type-B
3x 4 mm² (< 50m)
Outer Dimension: Ø 12-18 mm
IP55
IK10
-30 °C to + 50 °C
5 % - 95 % (Relative humidity, without dewdrops)
0 - 3.000m
-40 °C to + 80 °C
5 % - 95 % (Relative humidity, without dewdrops)
0 - 5.000m