Error diagnosis

Error
LED bar does not light up
Charging process is not
started
The vehicle not fully
charged / longer charging
time
Charging cable cannot be
un- plugged
LED bar flashes red
Operating instructions V 1.00 Document: V 1.00 / Document No.: 105728 │ Date 28.05.2018
Possible causes
No supply voltage
The charging station is defec- tive
The charging cable is not plugged
in correctly
The charging process was not
carried out correctly
The charging socket may be dirty or
damaged in the lock- ing area
The vehicle does not require energy
or it has an error
The vehicle is programmed to
charge at a later starting time
No enable due to external control
device (energy sup- plier,
photovoltaic system, ...)
Electricity reduction or inter- ruption
of charging by vehicle or charging
station due to high temperature
-
-
Charging process was not
completed by the vehicle
The charging socket may not unlock
due to tension on the charging
cable
Error
-
The charging station is defec- tive
Error diagnosis
Remedy
Check the RCD and line cir- cuit
breaker and switch on if necessary
Contact your service partner
Unplug the charging cable and plug
it in again
Follow the instructions in "Charging
process"
Clean the charging socket or have it
replaced
Check the vehicle
-
-
When the charging station has
cooled down, the charg- ing
process is continued and the
charging current may be increased
again.
Protect the vehicle and the charging
station from direct sunlight during
the charging procedure (carport,
garage, ...).
Visual inspection of the charging
socket to see if it is dirty, worn or
damaged
Contact your service partner, if
necessary
Complete the charging process
according to the in- structions of the
vehicle man- ufacturer
Press the plug in and con- nect
again to the vehicle. Then finish the
charging process again.
Errors must always be ac-
knowledged by unplugging the
charging cable. For more
information, see "FAQs" on the ABB
website.
Switch off the supply voltage of the
charging station (in- stalled or
superordinate RCD and line circuit
breaker). Un- plug the charging
cable from the vehicle and the
charging station. Switch on the
voltage supply again.
Contact your service partner
│20