Electrical Connections; Connecting To The Power Supply - tau K691M Guía Para La Instalación

Ocultar thumbs Ver también para K691M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
WARNINGS
This manual is designed to assist qualified installation personnel only. It contains no information that may be
of interest to final users. This manual is attached to the K691M control unit, therefore it may not be used for
different products!
Important warnings:
Disconnect the mains power supply to the board before accessing it.
The K691M control unit is suitable for the control of a direct-current electromechanical gearmotor for automat-
ing gates and doors of all kinds.
Any other use is considered improper and is consequently forbidden by current laws.
Please note that the automation system you are going to install is classifi ed as "machine construction" and
therefore is included in the application of European directive 2006/42/EC (Machinery Directive).
This directive includes the following prescriptions:
-
Only trained and qualified personnel should install the equipment;
-
the installer must first make a "risk analysis" of the machine;
-
the equipment must be installed in a correct and workmanlike manner in compliance with all the stand-
ards concerned;
-
after installation, the machine owner must be given the "declaration of conformity".
This product may only be installed and serviced by qualified personnel in compliance with current, laws,
regulations and directives.
When designing its products, TAU observes all applicable standards (please see the attached declaration
of conformity) but it is of paramount importance that installers strictly observe the same standards when
installing the system.
Unqualified personnel or those who are unaware of the standards applicable to the "automatic gates and
doors" category may not install systems under any circumstances.
Whoever ignores such standards shall be held responsible for any damage caused by the system!
Do not install the unit before you have read all the instructions.
INSTALLATION
Before proceeding, make sure the mechanical components work correctly. Also check that the
gear motor assembly has been installed according to the instructions. Then make sure that the
power consumption of the gear motor is not greater than 3A (otherwise the control panel may
not work properly).
THE EQUIPMENT MUST BE INSTALLED "EXPERTLY" BY QUALIFIED PERSONNEL AS REQUIRED BY LAW.
Note: it is compulsory to earth the system and to observe the safety regulations that are in force
in each country.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE PROPER WORKING OR-
DER OF THE EQUIPMENT AND CREATE HAZARDOUS SITUATIONS FOR PEOPLE. FOR THIS REASON THE
"MANUFACTURER" DECLINES ALL RESPONSIBILITY FOR ANY MALFUNCTIONING AND DAMAGES THUS
RESULTING.

1. ELECTRICAL CONNECTIONS

All electrical connections must be made withthe system disconnected from the power
supply.
1_
To open the protection cover and access the electronic control unit of T-SKY, press on the side of
the cover and turn the panel door.
2_
Route the connection cables to the various devices through the cable clamps, leaving a length
20÷30cm more than necessary. See para. 2.2 for the type of cables and figure 3 for connections.
3_
Make the connections as shown in the diagram in figure 36. Terminals are removable to facilitate
connections.

1.1 Connecting to the power supply

For electric power supply of T-SKY simply connect the 230 Vac line to the transformer safety fuse holder .
11

Publicidad

Tabla de contenido
loading

Tabla de contenido