AXIS Q3505–VE Fixed Dome Network Camera
Install the Hardware
Route the Cables
Note
See Hardware Overview on page 10.
Depending on whether you want to route the cables through or along the wall, follow the relevant
instructions below. To route cables through the wall:
1. Using the drill template drill 4 holes for mounting the bracket, and one or two holes as
required for routing the cable or cables in the wall.
2. Route the network cable (and the multicable if required) through the wall and through
the hole or holes in the mounting bracket.
The cables can be routed along the wall and through the side hole on the mounting bracket. To do
this detach the locking clip and side lid in the mounting bracket after attaching mounting bracket
to wall (see Attach Mounting Bracket to Wall on page 17). Use an appropriate conduit adaptor as
required (see www.axis.com for optional accessories). See Hardware Overview on page 10.
Mounting Bracket
The mounting bracket has 4 mounting patterns. The mounting patterns follow the standard for the
following mounting options:
•
: 4" square box
•
: standard-sized US double gang junction box
•
: 4" octagon box
•
: standard-sized US single gang junction box
16