Changing The Batteries - Seca 704 Manual De Instrucciones Y Garantía

Ocultar thumbs Ver también para 704:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 53
... the display shows
– Battery voltage is running low. Change the batteries in the next few days.
batt
...
appears in the display?
– Batteries are empty. Put in new batteries.
St0p
...
appears in the display?
– Maximum load has been exceeded.
... the display flashes?
– If you have just activated the Hold or Tare function, please wait until the scale has de-
tected a steady weight value. The display will then stop flashing.
– If there has been no activation of a function beforehand, remove the load from the scale
and wait until
0. 0
... the display
– The ambient temperature of the scale is too high or too low. Place the scale in an
ambient temperature between +10 °C and +40 °C. Wait about 15 minutes for the
scale to adapt to the ambient temperature and then weigh again.
E
... the display
and a number appear?
– Switch off the scale with the Start key and start the scale again. The scale will then
work normally again.
If this is not the case, disconnect the power supply by briefly removing the batteries. If
this measure is equally unsuccessful, inform the Service department.
8. Servicing/recalibration
Have the scale recalibrated by authorised persons in accordance with national legal re-
quirements. The year of initial calibration can be found behind the CE symbol on the rating
plate above the number of the appointed office, 0109 (Hessen Weights & Measures Of-
fice). Recalibration is essential if one or more security marks are damaged or the calibra-
tion counter does not match the number on the applicable calibration counter mark (cf.
page 20).
We recommend having your scale serviced by your local service agent before having it
recalibrated. seca Customer Service will be pleased to give you further assistance.

Changing the batteries

When
or
bAtt
6 type AA 1.5 V batteries.
– Push the battery compartment closure
towards "Battery" and open the cover.
– Take out the holder and batteries.
– Remove the used batteries and insert
new batteries in the holder.
Check that the polarity is correct.
24
?
is displayed, then weigh again.
appears?
appear in the display, you should change the batteries. You need

Publicidad

Tabla de contenido
loading

Tabla de contenido