Connection to the control signal terminal (continued)
Item
00h=disable mouse function, 01 ∼ 7Fh=start mouse function
MOUSE
COMMUNICATE
0Xh=8N1, 1Xh=7N1
X0h=1200bps, X1h=2400bps, X2h=4800bps, X3h=9600bps, X4h=19200bps
POWER
3Eh=power off (standby status), 3Fh=power on
01 ∼ 3Fh=Zoom +, 41 ∼ 7Fh=Zoom –
ZOOM
01 ∼ 3Fh=Focus +, 41 ∼ 7Fh=Focus –
FOCUS
MIRROR
00h=Normal, 01h=H : Invert, 02h=V : Invert, 03h=H & V : Invert
INPUT
11h=VIDEO, 21h=RGB1, 22h=RGB2
SYSTEM (VIDEO)
00h 00h=Auto, 00h 01h=NTSC, 00h 04h=NTSC4. 43
00h 02h=PAL, 00h 03h=SECAM, 00h 05h=M-PAL, 00h 06h=N-PAL
00h (low volume) ∼ 24h (high volume)
VOLUME
MUTE
00h=mute off, 01h=mute on
00h 00h 00h (dark) ∼ 00h 00h 24h (bright)
BRIGHT
00h 00h 00h (low) ∼ 00h 00h 24h (strong)
CONTRAST
00h 00h 00h (pale) ∼ 00h 00h 24h (dense)
COLOR
00h 00h 00h (reddish) ∼ 00h 00h 24h (greenish)
TINT
00h 00h 00h (soft) ∼ 00h 00h 24h (sharp)
SHARPNESS
00h 00h 00h ∼ 00h 00h 24h
H.PHASE
H.POSIT
00h 00h 00h 01h (Right) moves one step
00h 00h 00h 7Fh (Left) moves one step
H.SIZE
00h 00h 00h 01h (Large) moves two step
00h 00h 00h 7Fh (Small) moves two step
V.POSIT
00h 00h 00h 01h (Up) moves one step
00h 00h 00h 7Fh (Down) moves one step
00h 00h 00h (Light red) ∼ 00h 00h 24h (Dark red)
COLOR BALANCE R
00h 00h 00h (Light blue) ∼ 00h 00h 24h (Dark blue)
COLOR BALANCE B
AUTO ADJUST
00h (AUTO ADJUST (Play))
BLANK
0Xh=blanking off, 1Xh=blanking on
X=8 Black, X=9 Blue, X=F White
MAGNIFY
00h=normal display, 01h=zoom Magnify display or Magnify ratio up.
7Fh=zoom ratio down
FREEZE
00h=normal display, 01h=still image display
The command code configuration consists of a 2-byte command and the following data.
• The first byte of a command indicates the command type with 3 bits on the MSB side and the data length
with 4 bits on the LSB side.
Projector - computer
'0xH' : Error code
'1xH' : response code
'70H' : frame error code
'x' indicates the data length (example: x=2 means a 2-byte command).
• The second byte of a command indicates the command contents.
Command data chart
Data code
Computer - projector
'2xH' : inquiry code
'3xH' : setting code
'4xH' : default setting code
29

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp-x958eCp-x960wCp-x960e

Tabla de contenido