Mounting Instructions / Maintenance / Replacement
The product may only be connected by a certified electrician under consideration of the local regulations; the
same applies to the exhaust air connections.
The installer is responsible for perfect function at the installation site!
Only the Compair Flow 150 system of Naber recommended for air circulation and compatible with the cooktop
extractor fan may be used.
The nominal diameter of the recirculation ducts may not exceed 150 mm.
The following points absolutely must be observed in regard to air circulation:
-
Keep the air circulation paths as short as possible.
-
If possible, avoid sharp angles and lay the ducts in bends.
-
Never select a duct diameter smaller than 150 mm.
-
No bends/angles may be laid 50 cm in front of the fan component.
-
Always lay a straight piece of about 50 cm between two angles/bends.
-
During the installation, ensure that the recirculation unit is still accessible after completion of the kitchen
assembly. As such, it may be necessary to displace the base feet of the kitchen cupboards.
-
Ensure that above the activated carbon mat that there is sufficient distance to adjacent components. If
this is not taken into account, this could lead to congestion in the exhaust air. This results in a
considerable reduction in the extraction performance of the entire cooktop extraction system.
-
The clear base height must not be less than 100 mm.
-
During intended, private use there is no condensation formation due to the low frequency of use.
Mounting the Recirculation Unit:
1.
During installation of the kitchen cupboards ensure that the recirculation unit is also easily accessible
after installation. As such, it may be necessary to remove or displace the base feet.
2.
Install the BORA cooktop extractor unit with the respective fan component.
3.
A sealing tape is preinstalled on the recirculation unit
connection fitting.