Note: If pilot does not stay lit, refer to
Troubleshooting, page 22. Also contact a
qualified service technician or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to the desired heating level. The main
burner should light. Set control knob to
The thermostatic control used on this model differs from standard thermostats. Standard ther-
mostats simply turn the burner on and off. The thermostat used on this heater senses the room
temperature. At times the room may exceed the set temperature. If so, the burner will shut off.
The burner will cycle back on when room temperature drops below the set temperature. The
control knob can be set to any comfort level between Low (1) and HIGH (5).
Shutting Off Heater
Turn control knob clockwise
OFF position.
1. Remove 2 screws securing screen to
stove. Carefully lift and pull screen forward
to remove.
2. Follow steps 1 through 5 under Lighting
Instructions, page 17.
3. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
18
OPERATION
THERMOSTAT CONTROL OPERATION
TO TURN OFF GAS TO APPLIANCE
to the
MANUAL LIGHTING PROCEDURE
www.usaprocom.com
any heat level between HI (5) and LO (1).
Note: Please wait one minute after shut-
ting off fireplace to allow the control valve
to reset before starting again.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
PILOT position.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
5. Make sure the heater screen is in place
before operating heater.
to the