TROUBLESHOOTING
UNIPOWER 600.12Q and 600.24Q
Troubleshooting
3 short sound alarms
+
Blinking orange light
Long sound alarm
+
Blinking orange light
+
Unipower does not deliver current
anymore
Slow and short sound alarm
+ blinking green light
" Low battery warning"
Long sound alarm,
+
Blinking orange light
+
Unipower does not deliver current
anymore
Blinking green light
Unipower is off
36/68
Causes
Output short circuit
Overconsumption
Battery overvoltage
Discharged battery
24V>230V inverter :
battery not suitable (12V
instead of 24V)
Discharged battery
24V>230V inverter :
battery not suitable (12V
instead of 24V)
Overheating warning
Bad connection
.
WWW
UNITECK
Remedies
Check the connections of your
devices to supply.
Check that the power of the
connected device is compatible
with the power of the inverter or if
possible reduce the consumption of
the connected devices.
Check that the battery voltage is
compatible with the inverter.
Replace the battery if it is
defective.
Recharge it and/or reduce the
consumption of the connected
devices before the inverter puts
itself in protection.
Replace your 12V battery by a 24V
battery.
Recharge your battery or replace
it, if it is defective.
Replace your 12V battery by a 24V
battery.
Improve the ventilation, if possible
reduce the consumption of the
connected devices.
Check the inverter/battery
connection.
.