IMPORTANT: Installation must be carried out according to
the manufacturer's instructions. Incorrect installation may
cause harm and damage to people, animals or property,
for which the manufacturer accepts no responsibility.
Before carrying out any work on the electrical section of
the appliance, it must be disconnected from the mains.
Connection to a good earth wiring system is absolutely
essential.
The manufacturer accepts no responsibility for any incon-
venience caused by failure to comply with this rule.
DETAILS
The hob must be installed by a qualified electrician in line with
all electrical and installation requirements published by the
Institute of Electrical Engineers. We recommend that the appli-
ance is connected by a qualified electrician, who is a member
of the N.l.C.E l C. and who will comply with the l.E.E. and local
regulations.
Before carrying out the connection to the power supply, the
voltage rating of the appliance (stamped on the appliance iden-
tification plate) must be checked for correspondence to the
available mains supply voltage, and the mains electric wiring
should be capable of handling the appliance's power rating
(also indicated on the identification plate).
This appliance must be connected by a competent person,
using fixed wiring via a DOUBLE POLE SWITCHED FUSED SPUR
OUTLET (with 3 mm minimum distance between the contacts).
A double pole switch must be provided no further than 2 metres
from the appliance to the electrical supply. All supply current
and earth conductors must be able to withstand an ambient
temperature of 75°C.
After having installed the appliance, the power switch must
always be in a accessible position.
The wires in the mains lead are coloured in accordance with
the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live.
As the colours of the wires in the mains lead for the appliance,
may not correspond with the coloured markings identifying the
terminals in your spur box, proceed as follows:
1)The wire which is coloured green and yellow must be con-
nected to the terminal marked E (Earth) or
coloured.
2)The wire which is coloured blue must be connected to the ter-
minal marked N (Neutral), or coloured Black.
3)The wire which is coloured brown must be connected to the
terminal marked L (Live), or coloured Red.
Fig. 6.5
4 electrical plates models
for the UNITED KINGDOM
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
ON
FUSE
use a 30 AMP fuse
N.B. For connections to the mains power supply, never use
adaptors, reductions or multiple power points as these may
overheat and catch fire.
In the event that installation should require modifications to the
mains supply wiring system, it is recommended that a qualified
technician be called to carry out substitution.
The technician will also have to verify that the cross-section of the
electric cables on the power point match the appliance's power
rating.
If the hob surface is cracked disconnect the appliance from
the mains.
D
C
Fig. 6.6
ELECTRICAL CONNECTION
To connect the mains flex to the hob, proceed as follows:
Upturn the hob
Unscrew screws "A" and remove protection "B" (Fig. 6.8)
Insert connecting plates "C" into terminal block "D" (Fig. 6.6)
as shown in the diagram in Fig. 6.7.
Unscrew cable clamp "E" (Fig. 6.8)
Insert correct section and type mains flex (see special chap-
ter) through mains hitch "F" of protection "B," and connect
mains and earth wires to their respective terminals in block
"D," in accordance with the diagram shown in Fig. 6.7.
Tighten mains flex, and fix it with clamp "E."
Replace protection "B," keeping flex taut.
FEEDER SPECIAL CABLE SECTION - Type
or Green
"HO5V2V2-F"
resistance to temperatures of 90°C
230 VAC 50/60 Hz
Fig. 6.8
1
2
3
4
5
C
3 x 2,50 mm
F
230 V
50/60 Hz
1 2
3 4 5
PE
N
L
1
(L )
2
Fig. 6.7
2
A
B
F
E
D
43