Air Intake Connection - Royal MARY Generalidades - Advertencias - Instalación - Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.4

AIR INTAKE CONNECTION

It is necessary to provide an external air intake to
The dimensions of the hole must comply with the values
set forth in the table of technical data shown in the
"Product booklet".
• Is forbidden the intake of air for combustion from
• The combustion air intake should be protected by
an anti-insect grille and placed where it can not be
accidentally obstructed, and made in such a way that the
useful cross-section allows the right amount of oxygen
to reach the stove.
In the room where the stove is located, if there are one
or more extraction fans (exhaust hoods and the like),
there may be problems with combustion due to lack of
combustion air.
5.5
SMOKE OUTLET CONNECTION
with EN 13384-1.
• The SMOKE
should have the same cross section as the stove's smoke
• In order to connect the stove to the chimney you may
perform maximum 3 changes of direction that should not
exceed 90°, the fume duct should not exceed 2 metres
in length and 3 metres in total (
• if the outlet is placed on the ceiling, make sure that the
the direction.
• Follow the indications in the technical data sheet
regarding the chimney draught value.
5.6
FUMES DAMPER
INSTRUCTIONS FOR THE ASSEMBLY OF THE FUMES
DAMPER (-5.3-).
A.
Through the handle the damper may be opened or closed
to obtain the best regulation of the draft.
B.
Open damper (vertical position)
C. Close damper (horizontal position)
D. It is advisable to seal, with some heat resistant silicon the
damper around the fumes outlet in the position indicate
in the picture.
5.6.1
Valve use
The valve must be kept open while lighting up the
In case of low draught, it is possible to regulate the valve
in the intermediate position.
(-5.1-).
.
).
x ≤ 2 m
y ≥ 0,5 m
x + y ≤ 3 m
x
y
A
B
C
D
fig. 5.1
fig. 5.2
fig. 5.3
23

Publicidad

Tabla de contenido
loading

Tabla de contenido