Fitting guidelines
Connection diagram
Caution! Voltage of heating elements
is 230V. Caution! ln the event of any
connection the earth wire must be
connected to the
PE terminal.
For 230 V earthed one-phase
1
connection, bridges connect 1-2
terminals, earth wire to
For 400/230V earthed two-
2
phase connection, earth wire to
.
L1=R, L2=S, L3=T, N= neutral wire terminal, PE= earth wire terminal
Hob top
Work top
Bracket
The ceramic hob is manufactured to work with three-
phase alternating current (400V3N~50Hz).The
voltage rating of the ceramic hob heating elements
is 230V. Adapting the ceramic hob to operate
with one-phase current is possible by appropriate
bridging in the connection box according to the
connection diagram below. The connection diagram
is also found on the cover of the connection box.
Remember that the connection wire should match the
connection type and the power rating of the ceramic
hob. The connection cable must be secured in a
strain-relief clamp.
.
Screw
Recommen-
ded type of
connection
lead
H05VV-F
3G2.5
H05VV-F
4G2.5