INSTALLING THE WATER LINE (Cont.)
WHAT YOU WILL NEED (Cont.)
NOTE: The only GE Appliances, a Haier company,
approved plastic tubing is that supplied in Universal
Water Line Refrigerator Tubing kits. Do not use any
other plastic water supply line because the line is
under pressure at all times. Certain types of plastic
will crack or rupture with age and cause water
damage to your home.
• A water supply kit (containing tubing, shutoff valve
and fittings listed below) is available at extra cost
from your dealer or from cafeappliances.com/
parts. In Canada, visit cafeappliances.ca/parts.
• A cold water supply. The water pressure must be
between 20 and 120 p.s.i. (138-827 kPa).
• Power drill.
• 1/2" or adjustable wrench.
• Straight and Phillips blade screwdriver.
• Two 1/4" outer diameter compression nuts and
2 ferrules (sleeves)—to connect the copper tubing
to the shutoff valve and the refrigerator water valve.
OR
• If you are using a Universal Water Line Refrigerator
Tubing kit, the necessary fittings are preassembled
to the tubing.
• If your existing copper water line has a flared fitting
at the end, you will need an adapter (available at
plumbing supply stores) to connect the water line to
the refrigerator OR you can cut off the flared fitting
with a tube cutter and then use a compression
fitting. Do not cut formed end from Universal Water
Line Refrigerator tubing.
• Shutoff valve to connect to the cold water line.
The shutoff valve should have a water inlet
point of connection to the COLD WATER LINE.
Saddle-type shutoff valves are included in many
water supply kits. Before purchasing, make sure
a saddle-type valve complies with your local
plumbing codes.
24
Installation Instructions
Install the shutoff valve on the nearest frequently used
drinking water line.
SHUT OFF THE MAIN WATER
1
SUPPLY
Turn on the nearest faucet long enough to clear
the line of water.
CHOOSE THE VALVE
2
LOCATION
Choose a location for the valve that is easily
accessible. It is best to connect into the side of
a vertical water pipe. When it is necessary to
connection to the top or side, rather than at the
bottom, to avoid drawing off any sediment from
the water pipe.
DRILL THE HOLE FOR THE
3
VALVE
a self-piercing valve), using a sharp bit. Remove
any burrs resulting from drilling the hole in the
pipe.
Take care not to allow water to drain into the
drill.
ice production or smaller cubes.