The module will make a confirmation sound and the LED indicator will turn on momentarily each time a key is pressed. If more than
eight seconds elapse without any more keys being pressed after having pressed one, the module will make an error sound and delete
the register of keys pressed. The sequence will start again from its first code.
After entering the access code, you must press the key to validate. If the access code is correct, the module will make a confirmation
sound and activate the door release time set by micro-switches.
If 4 access codes incorrect are introduced in a space of time less than 30 seconds, the module is locked for 30 seconds, and not
accepting more input keys and sounds an alarm.
The function of each key is:
Digits 0 – 9: Valid for code number and code it.
-
Pushbutton KEY: Validates the entered access code.
-
Pushbutton LIGHT: Brightens the viewfinder while pressing (optional).
-
Pushbutton ESC: It is used to delete access codes.
-
The pushbuttons left arrow, right arrow and bell, no function assigned.
-
Guinaz SL P Industrial EL ESCOPAR P2 31350
Peralta Navarra SPAIN
T +34 948 713 182 F +34 948 750 659
comercial@guinaz.com
www.guinaz.com
8
*G503210*
G503210 REV.0