Simplicity SMF2 Manual De Instrucciones página 10

Tabla de contenido

Publicidad

2 Mount the Wall Plate
Solid concrete or concrete block
2-1 Mark the wall
2-2 Drill pilot holes
2-3 Insert anchors and lag bolts
10
[03]
[09]
For assistance in determining wall plate location, see Mount
Wizard at simplicityav.com
Level the wall plate [03] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage!
Mount the wall plate [03] directly onto the concrete surface.
Minimum solid concrete thickness: 203 mm (8 in.)
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x
16 in.)
CAUTION:
Avoid potential injuries or property damage!
Pilot holes MUST be drilled to a depth of 75 mm (3 in.) using
a 10 mm (3/8 in.) diameter drill bit.
Never drill into the mortar between blocks.
75mm
3 in.
Insert lag bolt anchors [09]. Then insert lag bolts [07] through
the washers [08] wall plate [03] and into the anchors.
CAUTION:
Improper use could reduce the holding power of
the lag bolt. To avoid potential injuries or property damage:
[03]
[03]
[07]
[08]
10 mm
13 mm
(3/8 in.)
(1/2 in.)
Be sure the anchors [09]
are seated fl ush with
the concrete surface.
Tighten the lag bolts [07]
only until the washers
[08] are pulled fi rmly
against the wall plate
[03].
DO NOT over-tighten the
lag bolts [07].
[09]
6903-002002 <05>

Publicidad

Tabla de contenido
loading

Tabla de contenido