7.6 Electrical connection
WARNING OF ELECTRICAL ENERGY!
RISK OF FATAL INJURY!
Live components have been installed near
this symbol. Covers bearing this sign may
only be removed by a certifi ed skilled electri-
cian.
•
The electrical connection must be carried out by a
qualifi ed electrician who is authorised to carry out such
work!
•
Statutory regulations and the connection specifi cations
issued by the local power supply company must be
strictly observed.
•
When connecting the appliance it must be ensured that
there is a device which makes it possible to universally
disconnect it from the mains with a contact opening
width of at least 3mm. Line-protecting switches, fuses
or contactors are suitable cut-out devices. When con-
necting and repairing the appliance disconnect it from
the electricity supply with one of these devices.
•
The earth wire must be suffi ciently long so that if the
strain relief fails, the live wires of the connecting cable
are subjected to tension before the earth wire.
•
Any superfl uous cable must be removed from the
installation area beneath the appliance.
•
Make sure that the local mains voltage is the same as
the voltage on the rating label.
•
Full protection against accidental contact must be en-
sured on installation.
•
Attention: Incorrect connection may result in the power
electronics unit being destroyed.
Power supply
Mains voltage: 380-415V 3N~, 50/60Hz
Component rated voltage: 220-240V
No mains cable present in the factory
•
To connect the appliance, unscrew the cover of the
connection socket on the underside of the appliance in
order to be able to access the terminal. After connect-
ing the appliance, replace the cover and secure the
connection cable with the strain relief clamp.
•
The connection cable must be at least H05 RR-F.
Instructions for assembly
Electrical connections: 6-pole connection
* Attention! Special power supply 220 - 240 V 3~ !
Mains cable available in the factory
•
The hob has been fi tted with a temperature-resistant
connection cable in the factory.
•
Connection to the mains is carried out in accordance
with the circuit diagram, unless the connection cable is
already fi tted with a plug.
•
If the mains cable of this appliance is damaged it will
need to be replaced with a special connection cable. In
order to avoid any risks, this must be carried out by the
manufacturer or his Customer Service.
Electrical connections
GB
35