manufacturers of batteries with cylindrical cells therefore recommend
reconditioning in case of cyclical application.
Reconditioning can be applied to wet-cell batteries to 'balance' the cells
and to prevent acid stratification.
Some manufacturers of battery chargers recommend impulse charging to
reverse the sulphation. However, most battery experts agree there is no
conclusive evidence that impulse charging is better than charging with a
low current / high voltage. This is confirmed by our own tests.
4.10. Lithium-ion (LiFePO₄) batteries
Li-ion batteries are not subject to sulphation and do not have to be fully
charged on a regular basis.
However, Li-ion batteries are highly sensitive to high or low voltages.
This is why Li-ion batteries are often equipped with an integrated system
for cell balancing and to protect against low voltages (UVP: Under Voltage
Protection).
Important note:
NEVER attempt to charge a lithium-ion battery if the temperature of the
battery is below 0°C.

4.11. Remote on-off

There are three ways to switch on the device:
1.
Short the L and H pins (factory default)
2.
Pull the H pin to a high level (e.g. the battery plus)
3.
Pull the L pin to a low level (e.g. the battery minus)
4.12. Alarm LED
If an error occurs, the ALARM LED will light up red. The status LEDs indicate the
type of error with a blink code. See the following table for the possible error
codes.
Error
LOW
Bulk time
protection
Internal
Error
2
For more information about lithium-ion batteries, see
battery-12,8v/
2
BULK
ABS
7
FLOAT
STORAGE
http://www.victronenergy.com/batteries/lithium-
ALARM

Publicidad

Tabla de contenido
loading