MS Schippers 440485 Serie Instrucciones Para El Uso página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

MS Heat mats/Controller
Instruction manual for MS Heat mats
Electric connection:
Electric consumption:
Safety classification:
Material:
Sensor of the heat mat:
Temperature:
Temperature of surroundings:
Capacity:
Installation:
FI- switch:
Use:
Connection method Z:
Installation:
The heat mats can only be used in combination with our MS controller 4404857.
The heat mats must be protected from sharp objects, they may not be bend or drilled. They
must be securely fastened through the existing holes onto a stable and even surface.
Before you hook up the heat mat to the power, the stainless steel cable protection hose must
be screwed onto the ½" fitting on the heat mat. Please place the washer between hose nut
and fitting.
This nut should not be fastened too tightly or it can damage the washer. Afterwards the cable
protection pipe must be fixed against the wall or pen separation and then fastened using
hose clamps.
Important is that the animals cannot reach the cable. Once installation is completed, the
upper opening of the cable protection pipe must be permanently sealed against moisture
using silicon or similar sealant.
The electric installation must be done as shown on the plan, which is found inside the
controller.
The hook-up must be done by an electrician.
Attention: When using heat mats without controller you may not install any additional
sources of heat.
When using the heat mats in combination with our controller you may use additional heat
sources.
Important though is that the same heat sources are used on the mother plate (the one with
the sensor) as on the following heat mats, which have no sensor.
4
230V / 50Hz
printed on each heat mat, on average 1.7 Watt per dm²
IPX7
GFK
resistance 4.7 k/Ohm at 20°C
adjustable with our controller 4404857, 25°C – 40°C
5°C – 40°C max.
80 kg/m²
only by an electrician
Installation of this switch is mandatory
Warming plate for animals
Electric cable cannot be replaced.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

4404857

Tabla de contenido