AVM™2
FUNCTION
PNEUMATIC DIAGRAM
1. Compressed air, 2. Vacuum, 3. Exhaust
COAX
®
Multi-stage ejector.
V1
Vacuum valve, NO or NC/NC 2 (NO shown. NC changes to NO if main power off, NC 2 stays NC if
main power off).
V2
Blow-off valve, NC. (Option: automatic blow-off, 1 sec)
S1/S2
Vacuum sensing port with two digital outlets, adjustable vacuum signal levels.
V3
Blow-off adjustment valve.
Note: The quality of the compressed air shall fulfil the requirements in DIN ISO 8573-1 class 4.
INTERNAL/EXTERNAL ELECTRICAL FUNCTIONALITY
V3
V1 V2 ES S1 S2
23