Wayne VIP Serie Manual Del Usuario
Ocultar thumbs Ver también para VIP Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions and Replacement Parts List
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description
This portable, submersible utility pump is
designed and in tend ed for non-automatic
use in water. The units are equipped with an
8-ft. 3-prong ground ing-type power cord.
The motor is oil filled and sealed for cooler
running and designed to operate under
water. The non-clogging impeller design
minimizes debris from stopping the pump.
The elbow fitting allows convenient
discharge through a garden hose.
IMPORTANT: THIS PUMP IS NOT
SUITABLE FOR AQUATIC LIFE!
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, call customer
service at 1-800-237-0987.
Safety Guidelines
This manual contains information that is very
important to know and understand. This
information is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS. To
help recognize this information, observe the
following symbols.
DANGER indicates
an imminently
hazardous situation which, if NOT avoided,
WILL result in death or serious injury.
WARNING indicates
a potentially hazardous
situation which, if NOT avoided, COULD result
in death or serious injury.
CAUTION indicates
a potentially hazardous
situation which, if NOT avoided, MAY result in
minor or moderate injury.
NOTICE indicates
important information,
that if NOT followed, MAY cause damage to
equipment.
General Safety
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2011, WAYNE / Scott Fetzer Company.
Submersible
Utility Pumps
Information
CALIFORNIA PROPOSITION 65
This product or its
power cord contains
chemicals known to the State of California
to cause cancer and birth defects or other
reproductive harm. Wash hands after
handling.
1. Know the pump application, limitations,
and potential hazards. Read these rules
and the instructions carefully. Failure to
follow them could cause serious bodily
injury and/or property damage.
GENERAL SAFETY
Do NOT
use to
pump flammable or explosive
fluids such as gasoline, fuel oil,
kerosene, etc. Do NOT use in
a flammable and/or explosive
atmosphere. Pump SHOULD be
used to pump clear water ONLY.
Personal injury and/or property damage
COULD result.
2. Make certain that the power source
con forms to the requirements of the
equipment.
Disconnect power
be fore ser vic ing. If the power dis­
con nect is out of sight, lock in the
open (OFF) po si tion and tag it to
prevent un ex pect ed ap pli ca tion
of pow er. Fail ure to do so COULD
result in fa tal elec tri cal shock!
3. Release all pressure within the system
before ser vic ing any component.
4. Drain all liquids from the system before
servicing.
5. Secure the discharge line before
starting the pump. An unsecured
For parts, product & service information
visit www.waynepumps.com
VIP Series
discharge line will whip, possibly caus-
ing personal injury and/or property
damage.
6. Check hoses for weak and worn
condition before each use, making
certain that all connections are secure.
7. Periodically inspect the pump and
system com po nents. Perform routine
maintenance as required (See Main te-
nance Section, on page 3).
This utility pump is
not constructed to handle
laun dry discharge or any other application which
may contain caustic chemicals and/or foreign ma te­
ri als. This pump is NOT a pond or waterfall pump –
use of the pump in these applications WILL void the
warranty. Pump damage COULD occur if the pump
is used in these
ap pli ca tions.
8. Provide a means of pressure relief for
pumps whose discharge line can be
shut-off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and prop er ly light ed; replace all
unused tools and equipment.
c. Keep visitors at a safe distance
from the work area.
10. When using an electrically driven
pump such as this, follow all electrical
and safety codes, as well as the most
recent National Electrical Code (NEC)
and the Oc cu pa tion al Safety and
Health Act (OSHA).
11. This equipment is only for use on 120
volt (single-phase) and is equipped
with an ap proved 3-conduc tor cord
and 3-prong, grounding-type plug as
shown in Figure 1.
320005-001 8/15

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Wayne VIP Serie

  • Página 1 General Safety REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. 320005-001 8/15 © 2011, WAYNE / Scott Fetzer Company. For parts, product & service information visit www.waynepumps.com...
  • Página 2 Operating Instructions and Replacement Parts List General Safety Application Operation Information (Continued) IMPORTANT: This pump is not designed Do NOT for use in septic tanks or underground touch pump, pump To reduce the risk of electric shock, the vaults to handle raw sewage or gray water. motor, water or discharge piping when the motor must be securely and adequately pump is connected to electrical power.
  • Página 3: Troubleshooting Chart

    Operating Instructions and Replacement Parts List in., therefore the pump will not remove 1. No oiling is required for this pump. all of the water. Shut off the pump 2. Disassembly of the motor prior to immediately if the unit has been expiration of war ran ty WILL void the operating and suddenly no water warranty.
  • Página 4 One Year Limited Warranty For one year from the date of purchase, WAYNE Water Systems (“WAYNE”) will repair or re place, at its option, for the original purchaser any part or parts of its Utility Pump, Sump Pumps or Water Pumps (“Product”) found upon examination by WAYNE to be defective in materials or work man ship.
  • Página 5: Directives De Sécurité

    6. Inspecter les tuyaux pour tout signe de MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. 320004-001 9/11 © 2011, WAYNE / Scott Fetzer Company. 5 Fr...
  • Página 6 Instructions D’Installation et D’Utilisation électrique, le moteur doit être bien mis à grisâtre. Elle ne doit jamais être utilisée chimiques. Remplacer le cordon la terre adéquatement. Ceci peut se dans des endroits dangereux ou explosifs. endommagé. faire en insérant la fiche directement Ne PAS utiliser le cordon d'alimentation ou 7.
  • Página 7: Guide De Dépannage

    Instructions D’Installation et D’Utilisation Entretien tension excessivement haute ou basse, l'atelier de réparation d'appareils un câblage inadéquat, une température électriques local. Toujours s'assurer d'eau excessive, une alimentation d'eau 3. L'entrée doit rester propre et libre de que la pompe est insuffisante, une température de l'air tout objet étranger et débris.
  • Página 8 Un An Garantie Limitée Pendant un an à compter de la date d’achat, WAYNE Water Systems (« WAYNE ») va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces de ses pompes utilitaires, pompes de puisard ou pompes à l'eau (« Produit ») déterminées défectueuses, par WAYNE, en termes de matériaux ou de fabrication.
  • Página 9: Descripción

    NO seguirla, le PODRÍA ocasionar daños al equipo. RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. 320004-001 9/11 © 2011, WAYNE / Scott Fetzer Company. 9 Sp...
  • Página 10: Funcionamiento

    Instrucciones de funcionamiento y de Instalacion 11. Esta bomba es sólo para usar con 120 IMPORTANTE: Esta bomba no está DE CONEXIÓN A TIERRA. CORTAR EL CABLE voltios (monofásico) y está equipada diseñada para usar en tanques sépticos ni O EL ENCHUFE ANULARÁ la garantía y PUEDE con un cable trifilar y un enchufe de en bóbedas subterráneas para manejar dejar la bomba inoperable.
  • Página 11: Guía De Diagnóstico De Averías

    Instrucciones de funcionamiento y de Instalacion desechos. toda la corriente antes de que se pueda agua está muy bajo y la bomba se ha dañar el motor. Cuando el motor se descebado. Use un trapeador o Esta bomba haya enfriado lo suficiente, el interruptor lampazo para quitar el resto del agua.
  • Página 12: Especificaciones

    Garantía Limitada Durante un año a partir de la fecha de compra, WAYNE Water Systems (“WAYNE”) reparará o reemplazará, según lo decida, para el comprador original, cualquier pieza o piezas de sus Bombas de uso general, Bombas para sumideros o Bombas de agua (“Producto”) que después de un examen sea(n) hallada(s) por WAYNE como defectuosa(s) en su material o mano de obra.